Cat EGP Switchgear
MX350 Controller

Technical Summary

Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications - -
Modes of Operation Multi-unit Island and multi-unit standby mode with optional redundant controls and components. - -
Application LV and MV (208V - 38 kV) - -
Rating Range - Switch Dependent -
Transfer Type - Application Dependent -
Switch Type - Application Dependent -

Generator Protective Devices

ANSI Protective Devices 15/25, 27/59, 81 O/U, 32, 40, 50, 51 - -

Environmental Parameters

Certifications IBC, CBC, UBC & OSHPD Certified - -
Control Panel Enclosure NEMA 1 or NEMA 3R Freestanding Construction - -
Operating Temperature 0°C to 50°C - -
Storage Temperature -20°C to +60°C - -
Low Voltage Standards NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 - -
Medium Voltage Standards NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 - -

Controller Specifications

Voltage Unbalance on Dropout for Source 1 and Source 2 - 5 to 20% of nominal -
Delay NeutralTransition Time Delays (DT,DW) - 0-10 minutes -
Control Power - 120 VAC -
Undervoltage Dropout for Source 1 and Source 2 - 75-99% of nominal -
Undervoltage Restore for Source 1 and Source 2 - 85-100% of nominal -
Overfrequency Dropout for Source 1 and Source 2 - 50.1 - 63 Hz -
Source Sensing - 120 - 690 VAC +/- 1% of nominal voltage (+/- .05 Hz, +/-.5 A) -
Delay for Engine Cool Down (U) - 0-60 minutes -
Underfrequency Restore for Source 1 and Source 2 - 45 - 59.5 Hz -
Load Control Relay Contacts (2) - 0-259 minutes -
Overvoltage Dropout for Source 1 and Source 2 - 105 - 110% of nominal -
Voltage Unbalance for Restore for Source 1 and Source 2 - 4 to 19% of nominal -
Storage Temperature - (-40˚C - 90˚C ) -
Underfrequency Dropout for Source 1 and Source 2 - 45 - 59.9 Hz -
Overfrequency Restore for Source 1 and Source 2 - 50 - 62.9 Hz -
Delay Transfer to Nonpreferred Source (W) - 0-5 minutes -
Operating Temperature Ambient - (-20˚C to 50˚C) -
Communications Interface - Optional - Serial RS-485 upt to 115.2 Kbps or TCP/IP (10/100 base-T) -
Overvoltage Restore for Source 1 and Source 2 - 103 - 108% of nominal -
Load Control Relay Contacts (1) - rated for 10A @ 24VDC or 120VAC -
Add a Similar Product:
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • DE800S GC Add
  • 3412C | 900 kVA 50Hz Generator Set Add
  • C27 Generator Set Add
  • 3412C Generator Set Add
  • C175-20 Add
  • 3606 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • 3412C | 750kVA 50Hz Generator Set Add