Compare Equipment Go Back
DG175-2 (Single-phase) |
Cat XLM Switchgear |
Cat Switchgear |
XQ570 Tier 4 Final - 455 ekW (568 kVA) |
|
Generator Set Specifications |
||||
---|---|---|---|---|
Frequency | 60 Hz | - | - | - |
Natural Gas Rating | 175 ekW | - | - | - |
Emissions/Fuel Strategy | U.S. EPA Certified for Non-Emergency Application | - | - | - |
Displacement | 864.71 in | - | - | - |
Fuel Type | Natural Gas | - | - | - |
Speed | 1800 rpm | - | - | - |
Engine Specifications |
||||
Engine Model | G14.2L Inline 6, 4 cycle, Spark Ignited | - | - | - |
Fuel System | Carburetor, Down Draft | - | - | - |
Aspiration | Turbocharged - Aftercooled | - | - | - |
Governor Type | Electronic | - | - | - |
Compression Ratio | 9.5:1 | - | - | - |
Bore | 5.31 in | - | - | - |
Stroke | 6.5 in | - | - | - |
Generator Set Dimensions |
||||
Length | 127.95 in | - | - | - |
Width | 52.93 in | - | - | - |
Height | 67.37 in | - | - | - |
Weight | 5756 lb | - | - | - |
Technical Summary |
||||
Configuration | - | Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications | - | - |
Modes of Operation | - | Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power | - | - |
Application | - | LV and MV ( 208V - 38 kV | - | - |
Technical Summary | - | - | Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers. | - |
Generator Protective Devices |
||||
ANSI Protective Devices | - | 15/25, 27/59, 81 O/U, 32, 40, 50, 51 | - | - |
Utility Protective Devices |
||||
ANSI Protective Devices | - | 15/25, 27/59, 81 O/U, 32, 40, 47, 50, 51, 86 | - | - |
Environmental Parameters |
||||
Certifications | - | IBS, CBC, UBC & OSHPD Certified | - | - |
Control Panel Enclosure | - | NEMA 1 or NEMA 3R, Freestanding Construction | - | - |
Operating Temperature | - | 0 degrees to 50 degrees C | - | - |
Storage Temperature | - | -20 degrees C to +60 degrees C | - | - |
Low Voltage Standards | - | NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 | - | - |
Medium Voltage Standards | - | NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 | - | - |
Enclosure Rating |
||||
Configuration | - | - | IP4X | - |
Operating Temperature |
||||
Operating Temperature | - | - | 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F) | - |
Dimensions |
||||
Standard Widths | - | - | 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A. | - |
Standard Heights | - | - | Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping | - |
Standard Depths | - | - | 300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers | - |
Height - Without Trailer | - | - | - | 102 in |
Length - Without Trailer | - | - | - | 240 in |
Width - Without Trailer | - | - | - | 96 in |
Weight with Lube Oil and Coolant, Without Trailer | - | - | - | 24125 lb |
Application |
||||
Application | - | - | LV 380…480 VAC, 50 Hz, 3-Phase. | - |
Modes of Operation |
||||
Modes of Operation | - | - | Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc. | - |
Generator Set |
||||
Rating Prime | - | - | - | 455 ekW (568 kVA) |
Frequency | - | - | - | 60 Hz |
Voltage | - | - | - | 120 - 600 V |
Rating Standby | - | - | - | 500 ekW (625 kVA) |
Engine |
||||
Engine | - | - | - | Cat C18 |
Fuel | - | - | - | Diesel |
Fuel Consumption |
||||
100% Load 60Hz | - | - | - | 35.9 gal/hr |
75% Load 60Hz | - | - | - | 28.3 gal/hr |
50% Load 60Hz | - | - | - | 20.5 gal/hr |
Noise rating (with enclosure) |
||||
Sound Power @ 7 meters (23 feet) @ All Ratings | - | - | - | 74 dB(A) |
Add a Similar Product:
- Cat Customizable Switchgear and Controls Add
- EMCP 4.4 Master Control Panel Add
- Cat EGP Switchgear Add
- Engine Paralleling and Integration Control (EPIC) Add
- Cat® BDP1000 Bi-Directional Power Inverter Add
- Energy Capacity Expansion (ECE) module Add
- Energy Time Shift (ETS) Module Add
- Temporary Connection Boxes Add
- XQP550 EU Stage V Add
- XQ425 Add