DG175-2 (Single-phase)
Cat XLM Switchgear
Cat Switchgear

Generator Set Specifications

Frequency 60 Hz - -
Natural Gas Rating 175 ekW - -
Emissions/Fuel Strategy U.S. EPA Certified for Non-Emergency Application - -
Displacement 864.71 in - -
Fuel Type Natural Gas - -
Speed 1800 rpm - -

Engine Specifications

Engine Model G14.2L Inline 6, 4 cycle, Spark Ignited - -
Fuel System Carburetor, Down Draft - -
Aspiration Turbocharged - Aftercooled - -
Governor Type Electronic - -
Compression Ratio 9.5:1 - -
Bore 5.31 in - -
Stroke 6.5 in - -

Generator Set Dimensions

Length 127.95 in - -
Width 52.93 in - -
Height 67.37 in - -
Weight 5756 lb - -

Technical Summary

Configuration - Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications -
Modes of Operation - Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power -
Application - LV and MV ( 208V - 38 kV -
Technical Summary - - Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.

Generator Protective Devices

ANSI Protective Devices - 15/25, 27/59, 81 O/U, 32, 40, 50, 51 -

Utility Protective Devices

ANSI Protective Devices - 15/25, 27/59, 81 O/U, 32, 40, 47, 50, 51, 86 -

Environmental Parameters

Certifications - IBS, CBC, UBC & OSHPD Certified -
Control Panel Enclosure - NEMA 1 or NEMA 3R, Freestanding Construction -
Operating Temperature - 0 degrees to 50 degrees C -
Storage Temperature - -20 degrees C to +60 degrees C -
Low Voltage Standards - NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 -
Medium Voltage Standards - NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 -

Enclosure Rating

Configuration - - IP4X

Operating Temperature

Operating Temperature - - 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)

Dimensions

Standard Widths - - 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
Standard Heights - - Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping
Standard Depths - - 300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers

Application

Application - - LV 380…480 VAC, 50 Hz, 3-Phase.

Modes of Operation

Modes of Operation - - Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc.
Add a Similar Product:
  • Cat Customizable Switchgear and Controls Add
  • EMCP 4.4 Master Control Panel Add
  • Cat EGP Switchgear Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • Temporary Connection Boxes Add
  • Energy Time Shift (ETS) Module Add
  • Energy Capacity Expansion (ECE) module Add
  • XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
  • XQP550 EU Stage V Add