Compare Equipment Go Back

3516 Diesel Generator Set
C280-16 Generator Set (Medium Speed)

Generator Set Specifications

Standby Rating 2000 kVA - 4000 (no fan)/3900/3620(no fan)/3500 ekW
Prime Power Rating 1825 kVA - 3600 (no fan)/3500/3300 (no fan)/3180 ekW
Emissions/Fuel Strategy Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 Low Fuel, Tier 2
Voltage 380 to 11000 Volts - 480 to 13800 Volts
Frequency 50 Hz 50 / 60 Hz 60 Hz
Speed 1500 rpm 900 / 1000 rpm 1800 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous Prime, Continuous Standby, Mission Critical, Prime, Continuous
Maximum Rating 2000 kVA 4840 ekW (60Hz), 6500 kVA (50Hz) 4000 ekW
Minimum Rating 1600 kVA 4400 ekW (60Hz), 5875 kVA (50Hz) 3150 ekW

Engine Specifications

Engine Model 3516 TA, V-16, 4-Stroke Water-Cooled Diesel C280-16, V-16,4-Stroke Water-Cooled Diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel
Displacement 4210.64 in³ 18032 in³ 6456.31 in³
Compression Ratio 13.0:1 13:01 15.3:1
Aspiration TA TA Turbo Aftercooled
Fuel System Mechanical unit injection Direct unit injection Common Rail
Governor Type Woodward Generator Set Monitoring System (GMS) ADEM� A4
Bore - 11 in 6.89 in
Stroke - 11.8 in 8.66 in

Generator Set Dimensions

Height - Maximum 93.2 in 156.6 in 150.7 in
Dry Weight - Genset (maximum) 33900 lb 141840 lb 66200 lb
Length - Maximum - 404 in 330.6 in
Width - Maximum - 99.62 in 127.7 in
Length - Minimum - - 261.5 in
Width - Minimum - - 85.4 in
Height - Minimum - - 87.6 in
Dry Weight - Genset (minimum) - - 55100 lb
Add a Similar Product:
  • 3612 Generator Set (Medium Speed) Add
  • 3616 Generator Set (Medium Speed) Add
  • C280-12 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-16 Tier 4 Final Add