3516 Diesel Generator Set

Product description

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
  • Standby Rating - 2000 kVA
  • Prime Power Rating - 1825 kVA
  • Emissions/Fuel Strategy - Low Fuel Consumption
  • Voltage - 380 to 11000 Volts
  • Frequency - 50 Hz
  • Speed - 1500 rpm
  • Duty Cycle - Standby, Mission Critical, Prime, Continuous
  • Maximum Rating - 2000 kVA
  • Minimum Rating - 1600 kVA
Engine Specifications
  • Engine Model - 3516 TA, V-16, 4-Stroke Water-Cooled Diesel
  • Bore - 6.69in
  • Stroke - 7.48in
  • Displacement - 4210.64in³
  • Compression Ratio - 13.0:1
  • Aspiration - TA
  • Fuel System - Mechanical unit injection
  • Governor Type - Woodward
Generator Set Dimensions
  • Length - Maximum - 232.9in
  • Width - Maximum - 90in
  • Height - Maximum - 93.2in
  • Dry Weight - Genset (maximum) - 33900lb
Standard Equipment:
  • Air Inlet System
    • Air cleaner; single element canister type
  • Air Inlet
    • Air cleaner
  • Cooling
    • Package mounted radiator
  • Exhaust
    • Exhaust flange outlet
  • Fuel
    • Secondary fuel filters
    • Fuel priming pump
    • Primary fuel filter with integral water separator
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
  • Power Termination
    • Busbar
  • Control Panel
    • EMCP 4 Genset controller
  • Control Panels
    • Over/under voltage (27/59)
    • Serial annunciator module data link
    • Communications:
    • Overcurrent (50/51)
    • Over/under frequency (81 o/u
    • Text alarm/event descriptions
    • Generator set packages include Caterpillar's voltage regulator
    • Programmable protective relaying functions:
    • 4 Programmable relay outputs (Form A)
    • Reverse power (kW) (32)
    • Emergency stop
    • Amps (per phase & average)
    • Oil pressure (psi, kPa or bar)
    • Operating hours
    • 24 Volt DC operation
    • Low oil pressure
    • 6 Customer programmable digital inputs
    • 1 Programmable digital outputs
    • 1 Programmable relay outputs (Form C)
    • Volts (L-L & L-N)
    • Number of I/O varies on options selected
    • RPM - DC volts
    • Low coolant level
    • kVAr-hr (total)
    • Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
    • kW-hr (total)
    • Failure to start (overcrank)
    • Environmental sealed front face
    • Power factor (per phase & average)
    • Accessory module data link
    • Generator mounted - rear facing
    • High coolant temperature
    • Overspeed
    • 3 Analog inputs
    • Frequency (Hz)
    • Warning/shutdown with common LED indication of shutdowns for
    • Coolant temperature
    • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min /max exciter. Limiter and exciter diode monitor
    • Customer data link (Modbus RTU)
    • kVA (per phase, average & percent)
    • Cat connect
    • Generator phase sequence
    • Reverse reactive power (kVAr) (32RV
    • DC volts
    • kW (per phase, average & percent)
    • kVAr (per phase, average & percent)
    • Emergency stop pushbutton
    • Digital indication for:
    • Low coolant temperature
    • EMCP 4.2B
  • Cooling System
    • Certified standard PGS provided
  • Exhaust System
    • Flanged faced outlet(s)
    • Dry exhaust manifold
  • Fuel System
    • Flexible fuel lines - shipped loose
    • Fuel priming pump
    • Fuel cooler; not included with packages without radiator
    • Secondary fuel filters
  • General
    • SAE standard rotation
    • Flywheel and flywheel housing - SAE No. 00
    • Right hand servicing
    • Caterpillar yellow with high gloss black rails and radiator
  • Generator And Attachments
    • Medium voltage:
    • Form wound
    • Winding temperature detectors
    • High voltage:
    • 3 Phase brushless, Salient pole
    • Permanent magnet excitation (PMG)
    • Permanent magnet excitation (PMG)
    • NEMA standard hole pattern
    • Internal excitation (IE)
    • Six lead
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
    • Low voltage:
    • Winding temperature detectors
    • NEMA standard hole pattern
    • Form wound
    • Winding temperature detectors
    • Random wound
    • Busbar connections, top center mounted, top cable entry
    • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
    • Anti-condensation space heater
    • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Governing System
    • ADEM A3
  • Literature
    • Parts book
  • Lubrication System
    • Gear type lube oil pump
    • Fumes disposal
    • Oil drain lines and valve
    • Lubricating oil
    • Oil filter, filler and dipstick
    • Integral lube oil cool
  • Mounting System
    • Anti-vibration mounts (shipped loose)
    • Rubber anti-vibration mounts - shipped loose
    • Rails - Engine/generator/radiator mounting
  • Starting System
    • Battery disconnect switch
    • Battery and battery rack w/cables
    • 45 Amp Charging alternator
    • 24 Volt electric starting motor
Optional Equipment:
  • Air Inlet System
    • Dual element air cleaner
    • Single element filter
  • Exhaust
    • Exhaust mufflers
  • Cooling System
    • Optional installed radiators
    • Coolant
    • Standard ambient ATAAC radiators
    • Optional installed ATAAC radiators
    • Standard ambient radiators
    • Water level switch gauges
  • Generator
    • Internal excitation (IE)
    • Anti-condensation heater
    • Oversize and premium generators
    • Permanent magnet excitation (PMG)
  • Crankcase System
    • No explosion relief valves
    • Ventilation system
    • Explosion relief valves
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Control Panels
    • Remote monitoring software
    • Generator temperature monitoring & protection
    • Load share module
    • Digital I/O module
    • EMCP 4.2B
  • Exhaust System
    • Exhaust offset
    • Tier 4 dosing cabinet
    • Flexible fittings
    • Mufflers
    • Tier 4 clean emissions module
    • Elbows
    • Flange and exhaust expanders
    • Tier 4 clean emission MOD Kits
    • Flanges
    • Clean emission parts
    • Y Adapters
  • Mounting
    • Spring type vibration isolators
    • IBC isolators
    • Rubber anti-vibration mounts
  • Fuel System
    • Fuel priming pumps (Tier 4) - Manual or electric
    • Primary fuel filter
  • Starting/charging
    • Jacket water heater
    • Oversize batteries
    • Battery chargers
    • Air starting motor with control and silencer
    • Heavy duty starting system
    • Charging alternator
  • General
    • Special paint (Colors other than Caterpillar yellow or high performance paints)
    • US aid emblem
  • Generators And Attachments
    • Thermostat for space heater
    • Alternator air cleaner
    • Differential current transformers (DCT)
    • Differential current transformers (DCT) 8.7 kV and 15 kV classes
    • Generator conversion
    • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
    • Space heater
  • Instrumentation
    • Pyrometer and thermocouples
  • Lubrication System
    • Oil level regulator
    • Prelube pumps
    • Lube oil in standard sump
  • Mounting System
    • Spring type vibration isolators
    • Puck style low efficiency isolators
    • IBC vibration isolators
  • Power Connections
    • Neutral ground connections
    • Center post busbars
    • Right side power connections
    • Rear power connections
    • 2700 Frame, four lead, four terminal
    • Left side power connections
    • Ground cables between generator and terminal box
    • Low voltage Circuit breakers
  • Special Tests / Reports
    • IBC Certification
    • Standard engine test charge
    • PGS Test report @ 1.0 power factor
    • Generator test report
    • Fuel consumption test
    • Canadian Standards Association certification
    • PGS Test report @ 0.8 power factor
    • OSHPD Certification
    • Torsional vibration analysis reports
    • Generator set fuel consumption test
  • Starting And Charging
    • Electric starting motors
    • Air pressure regulator
    • 24 Volt battery set - Dry
    • Engine barring device
    • Starter cover
    • Air starting motors
    • Jacket water heaters
    • 10, 20, 35 and 50 Amp Battery chargers
  • Extended Service Coverage
    • Platinum, Gold and Silver coverage
Compare Products