Net power advertised is the power available at the engine flywheel when the engine is equipped with a fan, air cleaner, clean emissions module and alternator.
Net power advertised is the power available at the engine flywheel when the engine is equipped with a fan, air cleaner, clean emissions module and alternator.
-
Note (2)
The following engine configurations are available: – Meets U.S. EPA Tier 4 Final and EU Stage V emission standards. – Noncertified that emits equivalent to U.S. EPA Tier 3.
Two engine emission configurations are available. One meets U.S. EPA Tier 4 Final, EU Stage V, Korea Stage V, and Japan 2014 emissions standards. The other meets Brazil MAR-1 emission standards, emitting equivalent to U.S. EPA Tier 3 and EU Stage IIIA.
-
Net Power - ISO 9249:2007
-
405 hp
-
Engine Power - ISO 14396:2002
-
426 hp
-
Peak Net Torque (1,300 rpm)
-
1479 lbf·ft
-
Maximum Altitude without Derating (U.S. EPA Tier 4 Final/EU Stage V)
-
9298 ft
-
Maximum Altitude without Derating (U.S. EPA Tier 3/EU Stage IIIA)
Cylinders, Double Acting - Left and Right Tilt, Bore and Stroke
140 mm × 230 mm (5.5 in × 9.1 in)
-
-
Pilot System
Variable displacement piston
-
-
Pilot Maximum Flow
13.7 gal/min
-
-
Pilot Relief Valve Setting
580 psi
-
-
Pump Flow at 1,800 rpm
-
30.9 gal/min
-
Main Relief Pressure
-
3771 psi
-
Maximum Supply Pressure
-
3495 psi
-
Cylinder, Double Acting - Tilt and Tip, Bore and Stroke
-
140 mm × 230 mm (5.5 in × 9.1 in)
-
Hydraulic System - Steering
Steering System - Circuit
Pilot, load sensing
Pilot operated, load sensing
-
Steering System - Pump
Piston, variable displacement
Variable displacement piston
-
Maximum Flow
65.8 gal/min
-
-
Relief Valve Setting - Steering
3495 psi
3481 psi
-
Total Steering Angle
86 °
-
-
Steering Cycle Times - High Idle
3.1 s
-
-
Steering Cycle Times - Low Idle
5.7 s
-
-
Bore
-
4.5 in
-
Stroke
-
22.7 in
-
Max Flow at 1,800 rpm
-
44.9 gal/min
-
Vehicle Articulation Angle
-
86°
-
Service Refill Capacities
Fuel Tank
209.5 gal (US)
206.6 gal (US)
-
Cooling System
31.7 gal (US)
30.6 gal (US)
-
Crankcase
15.9 gal (US)
-
-
Diesel Exhaust Fluid Tank
8.7 gal (US)
-
-
Transmission
31.7 gal (US)
17.4 gal (US)
-
Hydraulic System Factory Fill
63.4 gal (US)
-
-
Differential - Final Drives - Front
49.1 gal (US)
26.4 gal (US)
-
Differential - Final Drives - Rear
49.1 gal (US)
29.1 gal (US)
-
Hydraulic System - Tank Only
37 gal (US)
-
-
Note (1)
All non-road Tier 4 Final/Stage V diesel engines are required to use: – ULSD (ultra-low sulfur diesel fuel with 15 ppm of sulfur or less) or ULSD blended with the following lower-carbon intensity fuels** up to: • 20% biodiesel FAME (fatty acid methyl este
All nonroad Tier 4 Final, EU Stage V, and Japan 2014 (Tier 4 Final) diesel engines are required to use: – Ultra low sulfur diesel (ULSD) fuels containing 15 ppm (mg/kg) sulfur or less. – Cat engines are compatible with the following renewable, alternative
-
Engine Crankcase
-
9 gal (US)
-
Diesel Exhaust Fluid Tank (For Tier 4 Final/Stage V Only)
-
8.5 gal (US)
-
Hydraulic Tank Only
-
35.4 gal (US)
-
Hydraulic System - Implement/Steering
-
56.5 gal (US)
-
Air Conditioning System
Air Conditioning
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system co
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system co
-
Axles
Front
Fixed
Planetary – Fixed
-
Rear
Trunnion
Planetary – Oscillating
-
Oscillation Angle
±13°
±11°
-
Brakes
Brakes
ISO 3450: 2011
-
-
Sound Performance - Tier 4 Final / Stage V
Operator Sound Pressure Level (ISO 6396:2008)
72 dB(A)
73 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
113 dB(A)
113 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)**
109 dB(A)
110 dB(A)
-
Note (1)
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives”
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives”
-
Note (2)
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701
** European Union Directive “2000/14/EC” as amended by “2005/88/EC.” and UK Noise Regulation 2001 No. 1701
-
Note (3)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (4)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (5)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Sound Performance - Tier 3 / Stage IIIA
Operator Sound Pressure Level (ISO 6396:2008)
72 dB(A)
73 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
113 dB(A)
113 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)**
110 dB(A)
110 dB(A)
-
Note (1)
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives”
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives”
-
Note (2)
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701
** European Union Directive “2000/14/EC” as amended by “2005/88/EC.” and UK Noise Regulation 2001 No. 1701
-
Note (3)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (4)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (5)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.