Net power advertised is the power available at the engine flywheel when the engine is equipped with a fan, air cleaner, clean emissions module and alternator.
-
-
Note (2)
The following engine configurations are available: – Meets U.S. EPA Tier 4 Final and EU Stage V emission standards. – Noncertified that emits equivalent to U.S. EPA Tier 3.
-
-
Operating Specifications
Operating Weight
105271 lb
-
-
Blade Capacities
7.9 – 22.2 m3 (10.3 – 29.0 yd3)
-
-
Transmission
Transmission Type
Cat planetary power shift
-
-
Forward - 1
4.2 mile/h
-
-
Forward - 2
7.2 mile/h
-
-
Forward - 3
12.6 mile/h
-
-
Forward - 4
22 mile/h
-
-
Reverse - 1
4.2 mile/h
-
-
Reverse - 2
7.6 mile/h
-
-
Reverse - 3
13.3 mile/h
-
-
Direct Drive - Forward 1
Lock-up disabled
-
-
Direct Drive - Forward 2
7.7 mile/h
-
-
Direct Drive - Forward 3
13.7 mile/h
-
-
Direct Drive - Forward 4
23.9 mile/h
-
-
Direct Drive - Reverse 1
4.5 mile/h
-
-
Direct Drive - Reverse 2
8.1 mile/h
-
-
Direct Drive - Reverse 3
14.3 mile/h
-
-
Note
Travel speeds based on 35/65-R33 tire
-
-
Hydraulic System - Lift/Tilt
Lift/Tilt System - Circuit
Pilot operated LS valve with EH
-
-
Lift/Tilt System
Variable displacement piston
-
-
Maximum Flow at 1,900 rpm
153 gal/min
-
-
Relief Valve Setting - Lift/Tilt
4641 psi
-
-
Cylinders, Double Acting - Lift, Bore and Stroke
139.75 mm × 1021 mm (5.5 in × 40.2 in)
-
-
Cylinders, Double Acting - Left and Right Tilt, Bore and Stroke
140 mm × 230 mm (5.5 in × 9.1 in)
-
-
Pilot System
Variable displacement piston
-
-
Pilot Maximum Flow
13.7 gal/min
-
-
Pilot Relief Valve Setting
580 psi
-
-
Hydraulic System - Steering
Steering System - Circuit
Pilot, load sensing
-
-
Steering System - Pump
Piston, variable displacement
-
-
Maximum Flow
65.8 gal/min
-
-
Relief Valve Setting - Steering
3495 psi
-
-
Total Steering Angle
86 °
-
-
Steering Cycle Times - High Idle
3.1 s
-
-
Steering Cycle Times - Low Idle
5.7 s
-
-
Service Refill Capacities
Fuel Tank
209.5 gal (US)
-
-
Cooling System
31.7 gal (US)
-
-
Crankcase
15.9 gal (US)
-
-
Diesel Exhaust Fluid Tank
8.7 gal (US)
-
-
Transmission
31.7 gal (US)
-
-
Hydraulic System Factory Fill
63.4 gal (US)
-
-
Differential - Final Drives - Front
49.1 gal (US)
-
-
Differential - Final Drives - Rear
49.1 gal (US)
-
-
Hydraulic System - Tank Only
37 gal (US)
-
-
Note (1)
All non-road Tier 4 Final/Stage V diesel engines are required to use: – ULSD (ultra-low sulfur diesel fuel with 15 ppm of sulfur or less) or ULSD blended with the following lower-carbon intensity fuels** up to: • 20% biodiesel FAME (fatty acid methyl este
-
-
Air Conditioning System
Air Conditioning
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system co
-
-
Axles
Front
Fixed
-
-
Rear
Trunnion
-
-
Oscillation Angle
±13°
-
-
Brakes
Brakes
ISO 3450: 2011
-
-
Sound Performance - Tier 4 Final / Stage V
Operator Sound Pressure Level (ISO 6396:2008)
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)
113 dB(A)
-
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)**
109 dB(A)
-
-
Note (1)
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives”
-
-
Note (2)
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701
-
-
Note (3)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (4)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (5)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Sound Performance - Tier 3 / Stage IIIA
Operator Sound Pressure Level (ISO 6396:2008)
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)
113 dB(A)
-
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)**
110 dB(A)
-
-
Note (1)
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives”
-
-
Note (2)
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701
-
-
Note (3)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (4)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (5)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.