Compare Equipment Go Back
Cat Switchgear |
MX250 Microprocessor Controller |
|
|
Enclosure Rating |
|||
---|---|---|---|
Configuration | IP4X | - | - |
Operating Temperature |
|||
Operating Temperature | 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F) | - | - |
Dimensions |
|||
Standard Widths | 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A. | - | - |
Standard Heights | Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping | - | - |
Standard Depths | 300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers | - | - |
Technical Summary |
|||
Technical Summary | Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers. | - | - |
Rating Range | - | Switch Dependent | - |
Transfer Type | - | Application Dependent | - |
Switch Type | - | Application Dependent | - |
Application |
|||
Application | LV 380…480 VAC, 50 Hz, 3-Phase. | - | - |
Modes of Operation |
|||
Modes of Operation | Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc. | - | - |
Controller Specifications |
|||
Undervoltage Dropout for Source 1 and Source 2 | - | 75-98% of nominal | - |
Undervoltage Restore for Source 1 and Source 2 | - | 85-100% of nominal | - |
Underfrequency Dropout for Source 1 and Source 2 | - | 90-100% of nominal | - |
Delay for Engine Cool Down (U) | - | 0-60 minutes | - |
Delay Transfer to Nonpreferred Source (W) | - | 0-5 minutes | - |
Delay NeutralTransition Time Delays (DT,DW) | - | 0-10 minutes | - |
Storage Temperature | - | (-30˚C - 75˚C ), -22˚F - 167˚F | - |
Operating Temperature Ambient | - | 40 - 400 amp molded shell (-20˚C to 65˚C) , -4˚F to 149˚F 40 - 4000 amp all others (-20˚C to 60˚C), -4˚F to 149˚F |
- |
Add a Similar Product:
- MX150 Microprocessor Controller Add
- MX350 Controller Add
- CTS Series Automatic Transfer Switch Add
- CTSM and CTGM Series Manual Transfer Switches Add
- CTX Series Automatic Transfer Switch Add
- CTG Series Automatic Transfer Switch Add
- CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch Add
- Cat Customizable Switchgear and Controls Add
- CTE Series Automatic Transfer Switch Add
- Cat EGP Switchgear Add