Temporary Connection Boxes |
XQ425 |
Cat EGP Switchgear |
Cat Customizable Switchgear and Controls |
Cat Switchgear |
|
Technical Summary |
|||||
---|---|---|---|---|---|
Application | EMERGENCY, LEGALLY REQUIRED EMERGENCY AND STANDBY | - | LV and MV (208V - 38 kV) | LV and MV ( 208V - 38 kV) 50 / 60 Hz | - |
Module Type | LUG-TO-LUG, CAMLOCK AND ENCLOSED CIRCUIT BREAKER | - | - | - | - |
Rated Power | 200 - 4000 AMPS | - | - | - | - |
Configuration | - | - | Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications | Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc | - |
Modes of Operation | - | - | Multi-unit Island and multi-unit standby mode with optional redundant controls and components. | All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow | - |
Technical Summary | - | - | - | - | Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers. |
Generator Set |
|||||
Rating Prime | - | 340 ekW (425 kVA) | - | - | - |
Frequency | - | 50/60 Hz | - | - | - |
Voltage | - | 120 - 600 V | - | - | - |
Rating Standby | - | 375 ekW (469 kVA) | - | - | - |
Engine |
|||||
Engine | - | C13 | - | - | - |
Fuel | - | Diesel | - | - | - |
Dimensions |
|||||
Height - Without Trailer | - | 60 in | - | - | - |
Length - Without Trailer | - | 208.7 in | - | - | - |
Width - Without Trailer | - | 104 in | - | - | - |
Weight with Lube Oil and Coolant, Without Trailer | - | 14700 lb | - | - | - |
Standard Widths | - | - | - | - | 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A. |
Standard Heights | - | - | - | - | Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping |
Standard Depths | - | - | - | - | 300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers |
Fuel Consumption |
|||||
100% Load 60Hz | - | 25.1 gal/hr | - | - | - |
75% Load 60Hz | - | 19.2 gal/hr | - | - | - |
50% Load 60Hz | - | 13.6 gal/hr | - | - | - |
Noise rating (with enclosure) |
|||||
Sound Power @ 7 meters (23 feet) @ All Ratings | - | 74 dB(A) | - | - | - |
Generator Protective Devices |
|||||
ANSI Protective Devices | - | - | 15/25, 27/59, 81 O/U, 32, 40, 50, 51 | Per customer specification | - |
Environmental Parameters |
|||||
Certifications | - | - | IBC, CBC, UBC & OSHPD Certified | Per customer specification | - |
Control Panel Enclosure | - | - | NEMA 1 or NEMA 3R Freestanding Construction | Per customer specification | - |
Operating Temperature | - | - | 0°C to 50°C | Per customer specification | - |
Storage Temperature | - | - | -20°C to +60°C | Per customer specification | - |
Low Voltage Standards | - | - | NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 | Per customer specification | - |
Medium Voltage Standards | - | - | NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 | Per customer specification | - |
Utility Protective Devices |
|||||
ANSI Protective Devices | - | - | - | Per customer specification | - |
Enclosure Rating |
|||||
Configuration | - | - | - | - | IP4X |
Operating Temperature |
|||||
Operating Temperature | - | - | - | - | 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F) |
Application |
|||||
Application | - | - | - | - | LV 380…480 VAC, 50 Hz, 3-Phase. |
Modes of Operation |
|||||
Modes of Operation | - | - | - | - | Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc. |