Compare Equipment Go Back

XQ230 Rental Power
Cat Customizable Switchgear and Controls
Cat Switchgear
Cat® BDP1000 Bi-Directional Power Inverter

Generator Set

Rating Prime 182 ekW (228 kVA) - - -
Frequency 60 Hz - - -
Voltage 120 - 600 V - - -
Rating Standby 200 ekW (250 kVA) - - -

Engine

Engine Cat C7.1 - - -
Fuel Diesel - - -

Dimensions

Height - Without Trailer 78.5 in - - -
Length - Without Trailer 162.2 in - - -
Width - Without Trailer 62.8 in - - -
Weight with Lube Oil and Coolant, Without Trailer 8432 lb - - -
Standard Widths - - 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A. -
Standard Heights - - Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping -
Standard Depths - - 300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers -

Fuel Consumption

100% Load 60Hz 14.7 gal/hr - - -
75% Load 60Hz 10.8 gal/hr - - -
50% Load 60Hz 7.4 gal/hr - - -

Noise rating (with enclosure)

Sound Power @ 7 meters (23 feet) @ All Ratings 72 dB(A) - - -

Technical Summary

Configuration - Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc - -
Modes of Operation - All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow - -
Application - LV and MV ( 208V - 38 kV) 50 / 60 Hz - Energy Storage System
Technical Summary - - Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers. -
Module Type - - - Integral part of Power Grid Stabilization and Energy Time Shift modules
Rated Power - - - 1000 kVA (1000kW 1PF)

Generator Protective Devices

ANSI Protective Devices - Per customer specification - -

Utility Protective Devices

ANSI Protective Devices - Per customer specification - -

Environmental Parameters

Certifications - Per customer specification - -
Control Panel Enclosure - Per customer specification - -
Operating Temperature - Per customer specification - -
Storage Temperature - Per customer specification - -
Low Voltage Standards - Per customer specification - -
Medium Voltage Standards - Per customer specification - -

Enclosure Rating

Configuration - - IP4X -

Operating Temperature

Operating Temperature - - 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F) -

Application

Application - - LV 380…480 VAC, 50 Hz, 3-Phase. -

Modes of Operation

Modes of Operation - - Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc. -
Add a Similar Product:
  • Cat EGP Switchgear Add
  • Cat XLM Switchgear Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • EMCP 4.4 Master Control Panel Add
  • Energy Capacity Expansion (ECE) module Add
  • Energy Time Shift (ETS) Module Add
  • Temporary Connection Boxes Add
  • XQ425 Add
  • XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
  • XQP550 EU Stage V Add