Compare Equipment Go Back

Cat G3520H Combined Heat and Power (CHP) Solution
XQ570 Tier 4 Final - 455 ekW (568 kVA)
Cat Switchgear

Generator Set Specifications

Continuous Rating 2480 ekW @ 1.0pf - -
Fuel Type Natural Gas - -
Maximum Electrical Efficiency 42.40% - -
Frequency 60 Hz - -
RPM 1500 - -

Engine Specifications

Engine Model G3520H - -
Displacement 5956 in³ - -
Aspiration TA - -
Bore 6.7 in - -
Stroke 8.5 in - -
Fuel System Electronic Fuel Control Valve - -
Governor Type ADEM™ A4 - -
Compression Ratio 11.1 - -

Generator Set Dimensions

Length 302 in - -
Width 86 in - -
Height 97 in - -
Dry Weight - Genset 54675 lb - -
Weight 168000 lb - -

Generator Set

Rating Prime - 455 ekW (568 kVA) -
Frequency - 60 Hz -
Voltage - 120 - 600 V -
Rating Standby - 500 ekW (625 kVA) -

Engine

Engine - Cat C18 -
Fuel - Diesel -

Dimensions

Height - Without Trailer - 102 in -
Length - Without Trailer - 240 in -
Width - Without Trailer - 96 in -
Weight with Lube Oil and Coolant, Without Trailer - 24125 lb -
Standard Widths - - 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
Standard Heights - - Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping
Standard Depths - - 300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers

Fuel Consumption

100% Load 60Hz - 35.9 gal/hr -
75% Load 60Hz - 28.3 gal/hr -
50% Load 60Hz - 20.5 gal/hr -

Noise rating (with enclosure)

Sound Power @ 7 meters (23 feet) @ All Ratings - 74 dB(A) -

Enclosure Rating

Configuration - - IP4X

Operating Temperature

Operating Temperature - - 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)

Technical Summary

Technical Summary - - Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.

Application

Application - - LV 380…480 VAC, 50 Hz, 3-Phase.

Modes of Operation

Modes of Operation - - Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc.
Add a Similar Product:
  • Cat Customizable Switchgear and Controls Add
  • Cat XLM Switchgear Add
  • Cat EGP Switchgear Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • EMCP 4.4 Master Control Panel Add
  • Energy Capacity Expansion (ECE) module Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • Energy Time Shift (ETS) Module Add
  • Temporary Connection Boxes Add
  • XQP550 EU Stage V Add