Compare Equipment Go Back
Gas Generator G3512H |
Cat Switchgear |
XQ570 Tier 4 Final - 455 ekW (568 kVA) |
Temporary Connection Boxes |
|
Generator Set Specifications |
||||
---|---|---|---|---|
Continuous Rating | 1515 ekW / 1505 ekW @1.0pf | - | - | - |
Fuel Type | Natural Gas, Hydrogen Blend (up to 25%) | - | - | - |
Maximum Electrical Efficiency | 44.90% | - | - | - |
Frequency | 50 / 60 Hz | - | - | - |
RPM | 1500 rpm | - | - | - |
Engine Specifications |
||||
Engine Model | G3512H | - | - | - |
Displacement | 3574 in³ | - | - | - |
Aspiration | TA | - | - | - |
Bore | 6.7 in | - | - | - |
Stroke | 8.5 in | - | - | - |
Governor Type | ADEM A4 | - | - | - |
Generator Set Dimensions |
||||
Length | 223 in | - | - | - |
Width | 76 in | - | - | - |
Height | 91 in | - | - | - |
Dry Weight - Genset | 31085 lb | - | - | - |
Enclosure Rating |
||||
Configuration | - | IP4X | - | - |
Operating Temperature |
||||
Operating Temperature | - | 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F) | - | - |
Dimensions |
||||
Standard Widths | - | 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A. | - | - |
Standard Heights | - | Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping | - | - |
Standard Depths | - | 300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers | - | - |
Height - Without Trailer | - | - | 102 in | - |
Length - Without Trailer | - | - | 240 in | - |
Width - Without Trailer | - | - | 96 in | - |
Weight with Lube Oil and Coolant, Without Trailer | - | - | 24125 lb | - |
Technical Summary |
||||
Technical Summary | - | Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers. | - | - |
Application | - | - | - | EMERGENCY, LEGALLY REQUIRED EMERGENCY AND STANDBY |
Module Type | - | - | - | LUG-TO-LUG, CAMLOCK AND ENCLOSED CIRCUIT BREAKER |
Rated Power | - | - | - | 200 - 4000 AMPS |
Application |
||||
Application | - | LV 380…480 VAC, 50 Hz, 3-Phase. | - | - |
Modes of Operation |
||||
Modes of Operation | - | Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc. | - | - |
Generator Set |
||||
Rating Prime | - | - | 455 ekW (568 kVA) | - |
Frequency | - | - | 60 Hz | - |
Voltage | - | - | 120 - 600 V | - |
Rating Standby | - | - | 500 ekW (625 kVA) | - |
Engine |
||||
Engine | - | - | Cat C18 | - |
Fuel | - | - | Diesel | - |
Fuel Consumption |
||||
100% Load 60Hz | - | - | 35.9 gal/hr | - |
75% Load 60Hz | - | - | 28.3 gal/hr | - |
50% Load 60Hz | - | - | 20.5 gal/hr | - |
Noise rating (with enclosure) |
||||
Sound Power @ 7 meters (23 feet) @ All Ratings | - | - | 74 dB(A) | - |
Add a Similar Product:
- Cat Customizable Switchgear and Controls Add
- Cat XLM Switchgear Add
- EMCP 4.4 Master Control Panel Add
- Cat EGP Switchgear Add
- Engine Paralleling and Integration Control (EPIC) Add
- Cat® BDP1000 Bi-Directional Power Inverter Add
- Energy Time Shift (ETS) Module Add
- Energy Capacity Expansion (ECE) module Add
- XQP550 EU Stage V Add
- XQ425 Add