Compare Equipment Go Back

3512 Generator Set
C280-12 Generator Set (Medium Speed)

Generator Set Specifications

Standby Rating 1400/1250 kVA - -
Prime Power Rating 1275/1150 kVA - -
Emissions/Fuel Strategy Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 -
Voltage 380 to 415 Volts - -
Frequency 50 Hz 50 / 60 Hz -
Speed 1500 rpm 900 / 1000 rpm -
Duty Cycle Standby, Mission Critical, Prime, Continuous Prime, Continuous -
Maximum Rating 1400 kVA 3640 ekW (60Hz), 4850 kVA (50Hz) -
Minimum Rating 1000 kVA 3300 ekW (60Hz), 4400 kVA (50Hz) -

Engine Specifications

Engine Model 3512 TA, V-12, 4-Stroke Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel -
Bore 6.69 in 11 in -
Stroke 7.48 in 11.8 in -
Displacement 3161.03 in³ 13524 in³ -
Compression Ratio 13.5:1 13:01 -
Aspiration TA TA -
Fuel System Direct Unit Injection Direct unit injection -
Governor Type Woodward Generator Set Monitoring System (GMS) -

Generator Set Dimensions

Length - Minimum 202.7 in - -
Length - Maximum 206.6 in 404 in -
Width - Maximum 77.8 in 99.62 in -
Height - Maximum 93.2 in 156.6 in -
Dry Weight - Genset (minimum) 22650 lb - -
Dry Weight - Genset (maximum) 23170 lb 112690 lb -
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3616 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-20 Add
  • 3606 Generator Set (Medium Speed) Add