Option 2 - China Nonroad Stage III emissions standards, equivalent to U.S. EPA Tier 2
-
-
Engine Power - ISO 14396:2002
786 hp
-
-
Gross Power - SAE J1995:2014
766 hp
562 hp
-
Net Power - SAE J1349:2011 - High Ambient
648 hp
-
-
Engine Power - ISO 14396: 2002
752 hp
-
-
Bore
5.4 in
5.7 in
-
Stroke
6 in
7.2 in
-
Displacement
1649.5 in³
1105 in³
-
Peak Torque - Speed
2624 lb/ft
-
-
Torque Rise
18 %
52 %
-
Note
Net power advertised is the power available at the flywheel when the engine is equipped with fan at minimum speed, air intake system, exhaust system, and alternator.
-
-
Net Power - SAE J1349:2011
-
496 hp
-
Peak Power Speed
-
1500 r/min
-
Peak Torque - 1,300 rpm
-
2092 lb/ft
-
Note (1)
-
Net power advertised is the power available at the engine flywheel when the engine is equipped with a fan, air cleaner, clean emissions module and alternator.
-
Note (2)
-
The following engine configurations are available: – Meets U.S. EPA Tier 4 Final and EU Stage V emission standards. – Noncertified that emits equivalent to U.S. EPA Tier 3.
-
Operating Specifications
Operating Weight
165089 lb
105271 lb
-
Blade Capacity Range
20.8 yd³
-
-
Blade Capacities
-
7.9 – 22.2 m3 (10.3 – 29.0 yd3)
-
Transmission
Transmission Type
Cat Planetary Power Shift
Cat planetary power shift
-
Converter Drive - Forward 1
4.5 mile/h
-
-
Converter Drive - Forward 2
8.3 mile/h
-
-
Converter Drive - Forward 3
14.2 mile/h
-
-
Converter Drive - Reverse 1
4.9 mile/h
-
-
Converter Drive - Reverse 2
9.1 mile/h
-
-
Converter Drive - Reverse 3
15.5 mile/h
-
-
Direct Drive - Forward 1
Lock-up disabled
Lock-up disabled
-
Direct Drive - Forward 2
8.5 mile/h
7.7 mile/h
-
Direct Drive - Forward 3
15.2 mile/h
13.7 mile/h
-
Direct Drive - Reverse 1
5.4 mile/h
4.5 mile/h
-
Direct Drive - Reverse 2
9.6 mile/h
8.1 mile/h
-
Direct Drive - Reverse 3
16.4 mile/h
14.3 mile/h
-
Note
Travel speeds based on 45/65-45 L-5 46 ply tires.
Travel speeds based on 35/65-R33 tire
-
Forward - 1
-
4.2 mile/h
-
Forward - 2
-
7.2 mile/h
-
Forward - 3
-
12.6 mile/h
-
Forward - 4
-
22 mile/h
-
Reverse - 1
-
4.2 mile/h
-
Reverse - 2
-
7.6 mile/h
-
Reverse - 3
-
13.3 mile/h
-
Direct Drive - Forward 4
-
23.9 mile/h
-
Hydraulic System - Lift/Tilt
Output at 2,000 rpm and 6900 kPa (1,000 psi)
82 gpm
-
-
Cylinders, Double Acting - Lift, Bore and Stroke
133 mm × 1535 mm (5.25 in × 60.4 in)
139.75 mm × 1021 mm (5.5 in × 40.2 in)
-
Cylinder, Double Acting - Tilt and Tip, Bore and Stroke
Cylinders, Double Acting - Left and Right Tilt, Bore and Stroke
-
140 mm × 230 mm (5.5 in × 9.1 in)
-
Pilot System
-
Variable displacement piston
-
Pilot Maximum Flow
-
13.7 gpm
-
Pilot Relief Valve Setting
-
580 psi
-
Hydraulic System - Steering
Steering System - Circuit
Pilot, load sensing
Pilot, load sensing
-
Steering System - Pump
Piston, variable displacement
Piston, variable displacement
-
Minimum Turning Radius - Over Blade
34 ft
-
-
Total Steering Angle
35 °
86 °
-
Maximum Flow
94.3 gpm
65.8 gpm
-
Relief Valve Setting
4500 psi
-
-
Relief Valve Setting - Steering
-
3495 psi
-
Steering Cycle Times - High Idle
-
3.1 s
-
Steering Cycle Times - Low Idle
-
5.7 s
-
Service Refill Capacities
Fuel Tank - Standard
286.6 gal (US)
-
-
Cooling System
54.9 gal (US)
31.7 gal (US)
-
Crankcase
20 gal (US)
15.9 gal (US)
-
Transmission
29.1 gal (US)
31.7 gal (US)
-
Differential - Final Drives - Front
71.6 gal (US)
49.1 gal (US)
-
Differential - Final Drives - Rear
68.9 gal (US)
49.1 gal (US)
-
Hydraulic System - Implement and Hydraulic Fan
68.9 gal (US)
-
-
Hydraulic System - Steering and Braking
34.9 gal (US)
-
-
Fuel Tank
-
209.5 gal (US)
-
Diesel Exhaust Fluid Tank
-
8.7 gal (US)
-
Hydraulic System Factory Fill
-
63.4 gal (US)
-
Hydraulic System - Tank Only
-
37 gal (US)
-
Note (1)
-
All non-road Tier 4 Final/Stage V diesel engines are required to use: – ULSD (ultra-low sulfur diesel fuel with 15 ppm of sulfur or less) or ULSD blended with the following lower-carbon intensity fuels** up to: • 20% biodiesel FAME (fatty acid methyl este
-
Air Conditioning System
Air Conditioning
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system co
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system co
-
Axles
Front
Fixed
Fixed
-
Rear
Trunnion
Trunnion
-
Oscillation Angle
8.5 °
±13°
-
Brakes
Brakes
Meets ISO 3540:2011
ISO 3450: 2011
-
Sound Performance - Tier 4 Final / Stage V
Operator Sound Pressure Level (ISO 6396:2008)
72 dB(A)
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
116 dB(A)
113 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)*
114 dB(A)
-
-
Note (1)
*Sound suppression equipped
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives”
-
Note (2)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701
-
Note (3)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
Note (4)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
Machine Sound Power Level (ISO 6395:2008)**
-
109 dB(A)
-
Note (5)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Sound Performance - Tier 2
Operator Sound Pressure Level (ISO 6396:2008)
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)
116 dB(A)
-
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)*
114 dB(A)
-
-
Note (1)
*Sound suppression equipped
-
-
Note (2)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (3)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (4)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Cab
ROPS/FOPS
ISO 3471:2008 and ISO 3449:2005 Level II Standards
-
-
Dimensions (Approximate)
Height - Top of ROPS
17.2 ft
-
-
Height - Top of Exhaust Pipe
16.6 ft
-
-
Height - Top of Hood
12.7 ft
-
-
Ground Clearance
2 ft
-
-
Centerline of Front Axle to Hitch
7.5 ft
-
-
Centerline of Rear Axle to Edge of Bumper
12.5 ft
-
-
Wheel Base
15.1 ft
-
-
Length - With Blade on Ground
36.5 ft
-
-
Sound Performance - Tier 3 / Stage IIIA
Operator Sound Pressure Level (ISO 6396:2008)
-
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
-
113 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
-
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)**
-
110 dB(A)
-
Note (1)
-
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives”
-
Note (2)
-
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701
-
Note (3)
-
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
Note (4)
-
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
Note (5)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.