Compare Equipment Go Back

C2.2 | DE18E3 50Hz EU IIIA EMISSIONS COMPLIANT
C280-16 Generator Set (Medium Speed)
C280-6 Generator Set (Medium Speed)
3608 Generator Set (Medium Speed)
3612 Generator Set (Medium Speed)
3606 Generator Set (Medium Speed)
3516E Generator Set
3612 Generator Set (Medium Speed)

Generator Set Specifications

Minimum Rating 18 kVA 4400 ekW (60Hz), 5875 kVA (50Hz) 1650 ekW (60Hz), 2200 kVA (50Hz) 1830 ekW 3300 ekW 1775 kVA 2725 kVA 4400 kVA
Maximum Rating 18 kVA 4840 ekW (60Hz), 6500 kVA (50Hz) 1820 ekW (60Hz), 2425 kVA (50Hz) 2660 ekW 4000 ekW 2688 kVA 3500 kVA 4850 kVA
Emissions/Fuel Strategy R96/EUIIIa Equivalent EPA Tier 4 Final, IMO Tier 2 IMO Tier 2 Low Fuel Consumption Low Fuel Consumption Low Fuel Consumption U.S. EPA Cert. Tier 2 / Low NOx Low Fuel Consumption
Voltage 200 to 400 Volts - - - - - 380 to 11000 volts -
Frequency 50 Hz 50 / 60 Hz 50 / 60 Hz 60 Hz 60 Hz 50 Hz 50 Hz 50 Hz
Duty Cycle Standby, Prime Prime, Continuous Prime, Continuous Standby, Prime, Continuous Prime, Continuous Continuous Standby, Mission Critical, Prime Prime, Continuous
Speed - 900 / 1000 rpm 900 / 1000 rpm 720 & 900 rpm 720 & 900 rpm 750 & 1000 rpm 1500 rpm 750 & 1000 rpm
Standby Rating - - - - - - 3500/3250/3000 kVA -
Prime Power Rating - - - - - - 3175/2950/2725 kVA -

Engine Specifications

Aspiration Turbocharged TA TA TA TA TA ATAAC TA
Engine Model - C280-16, V-16,4-Stroke Water-Cooled Diesel C280-6, I-6,4-Stroke Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel 3612 V-12,4-Stroke Water-Cooled Diesel 3606 I-6, 4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke Water-Cooled Diesel 3612 V-12,4-Stroke Water-Cooled Diesel
Bore - 11 in 11 in 11 in 11 in 11 in 6.69 in 11 in
Stroke - 11.8 in 11.8 in 11.8 in 11.8 in 11.8 in 8.46 in 11.8 in
Displacement - 18032 in³ 111 in³ 9064 in³ 13524 in³ 6762 in³ 4765 in³ 13524 in³
Compression Ratio - 13:01 13:01 13:01 13:01 13:01 14.0:1 13:01
Fuel System - Direct unit injection Direct unit injection Direct unit injection Direct unit injection Direct unit injection Electronic Unit Injection Direct unit injection
Governor Type - Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Adem™ A5 Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Maximum - 404 in 404 in 404 in 404 in 404 in 318.4 in 404 in
Width - Maximum - 99.62 in 99.62 in 99.62 in 99.62 in 99.62 in 104 in 99.62 in
Height - Maximum - 156.6 in 156.6 in 156.6 in 156.6 in 156.6 in 131.6 in 156.6 in
Dry Weight - Genset (maximum) - 141840 lb 74970 lb 91050 lb 112690 lb 74970 lb 45651 lb 112690 lb
Length - Minimum - - - - - - 313.4 in -
Width - Minimum - - - - - - 104 in -
Height - Minimum - - - - - - 131.6 in -
Dry Weight - Genset (minimum) - - - - - - 44930 lb -
Add a Similar Product:
  • 3616 Generator Set (Medium Speed) Add
  • C280-12 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C175-20 Add
  • C175-16 Tier 4 Final Add
  • 3516E Low Voltage Generator Set Add
  • C175-16 Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Generator Set Add