Compare Equipment Go Back

C32 | 1500 kVA 50Hz Generator Set
3606 Generator Set (Medium Speed)
3612 Generator Set (Medium Speed)
C280-16 Generator Set (Medium Speed)
C280-6 Generator Set (Medium Speed)
3516E Low Voltage Generator Set
3608 Generator Set (Medium Speed)
3516E Generator Set

Generator Set Specifications

Maximum Rating 1500 kVA 2688 kVA 4000 ekW 4840 ekW (60Hz), 6500 kVA (50Hz) 1820 ekW (60Hz), 2425 kVA (50Hz) 3000 ekW 2660 ekW 3500 kVA
Minimum Rating 910 kVA 1775 kVA 3300 ekW 4400 ekW (60Hz), 5875 kVA (50Hz) 1650 ekW (60Hz), 2200 kVA (50Hz) 2725 ekW 1830 ekW 2725 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions Low Fuel Consumption Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 IMO Tier 2 Tier 2 Low Fuel Consumption U.S. EPA Cert. Tier 2 / Low NOx
Voltage 400 to 3300 Volts - - - - 416 to 13,800 Volts - 380 to 11000 volts
Frequency 50 Hz 50 Hz 60 Hz 50 / 60 Hz 50 / 60 Hz 60 Hz 60 Hz 50 Hz
Speed 1500 rpm 750 & 1000 rpm 720 & 900 rpm 900 / 1000 rpm 900 / 1000 rpm 1800 rpm 720 & 900 rpm 1500 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous Continuous Prime, Continuous Prime, Continuous Prime, Continuous Standby, Mission Critical, Prime Standby, Prime, Continuous Standby, Mission Critical, Prime
Standby Rating - - - - - 3000 ekW - 3500/3250/3000 kVA
Prime Power Rating - - - - - 2725 ekW - 3175/2950/2725 kVA

Engine Specifications

Engine Model C32 TA, V-12, 4-Stroke Water-Cooled Diesel 3606 I-6, 4-Stroke Water-Cooled Diesel 3612 V-12,4-Stroke Water-Cooled Diesel C280-16, V-16,4-Stroke Water-Cooled Diesel C280-6, I-6,4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke, Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke Water-Cooled Diesel
Bore 5.71 in 11 in 11 in 11 in 11 in 6.69 in 11 in 6.69 in
Stroke 6.38 in 11.8 in 11.8 in 11.8 in 11.8 in 8.47 in 11.8 in 8.46 in
Displacement 1958.86 in³ 6762 in³ 13524 in³ 18032 in³ 111 in³ 4765 in³ 9064 in³ 4765 in³
Compression Ratio 15.0:1 13:01 13:01 13:01 13:01 13.9:1 / 14.3:1 13:01 14.0:1
Aspiration Turbocharged, Air to Air Aftercooled TA TA TA TA ATAAC TA ATAAC
Fuel System MEUI Direct unit injection Direct unit injection Direct unit injection Direct unit injection MEUI Direct unit injection Electronic Unit Injection
Governor Type Adem™A4 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Adem™ A5 Generator Set Monitoring System (GMS) Adem™ A5

Generator Set Dimensions

Length - Minimum 164 in - - - - - - 313.4 in
Length - Maximum 176.6 in 404 in 404 in 404 in 404 in 302.4 in 404 in 318.4 in
Width - Minimum 66.3 in - - - - - - 104 in
Width - Maximum 87.8 in 99.62 in 99.62 in 99.62 in 99.62 in 113.2 in 99.62 in 104 in
Height - Minimum 85.1 in - - - - - - 131.6 in
Height - Maximum 86.4 in 156.6 in 156.6 in 156.6 in 156.6 in 143.3 in 156.6 in 131.6 in
Dry Weight - Genset (minimum) 14700 lb - - - - - - 44930 lb
Dry Weight - Genset (maximum) 17855 lb 74970 lb 112690 lb 141840 lb 74970 lb 44930 lb 91050 lb 45651 lb
Add a Similar Product:
  • 3616 Generator Set (Medium Speed) Add
  • C280-12 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C175-20 Add
  • C175-16 Tier 4 Final Add
  • C175-16 Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Generator Set Add