Compare Equipment Go Back

3412C | 800 kVA 50Hz Generator Set
C280-8 Generator Set (Medium Speed)
C280-16 Generator Set (Medium Speed)
3612 Generator Set (Medium Speed)
C280-12 Generator Set (Medium Speed)
3516E Generator Set

Generator Set Specifications

Maximum Rating 800 kVA 2420 ekW (60Hz), 3250 kVA (50Hz) 4840 ekW (60Hz), 6500 kVA (50Hz) 4850 kVA 3640 ekW (60Hz), 4850 kVA (50Hz) 4000 ekW 3500 kVA
Minimum Rating 725 kVA 2200 ekW (60Hz), 2938 kVA (50Hz) 4400 ekW (60Hz), 5875 kVA (50Hz) 4400 kVA 3300 ekW (60Hz), 4400 kVA (50Hz) 3150 ekW 2725 kVA
Emissions/Fuel Strategy Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 EPA Tier 4 Final, IMO Tier 2 Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 Low Fuel, Tier 2 U.S. EPA Cert. Tier 2 / Low NOx
Voltage 380 to 415 Volts - - - - 480 to 13800 Volts 380 to 11000 volts
Frequency 50 Hz 50 / 60 Hz 50 / 60 Hz 50 Hz 50 / 60 Hz 60 Hz 50 Hz
Speed 1500 rpm 900 / 1000 rpm 900 / 1000 rpm 750 & 1000 rpm 900 / 1000 rpm 1800 rpm 1500 rpm
Duty Cycle Standby, Prime Prime, Continuous Prime, Continuous Prime, Continuous Prime, Continuous Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime
Standby Rating - - - - - 4000 (no fan)/3900/3620(no fan)/3500 ekW 3500/3250/3000 kVA
Prime Power Rating - - - - - 3600 (no fan)/3500/3300 (no fan)/3180 ekW 3175/2950/2725 kVA

Engine Specifications

Engine Model 3412C TA, V-12, 4-Stroke Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel C280-16, V-16,4-Stroke Water-Cooled Diesel 3612 V-12,4-Stroke Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke Water-Cooled Diesel
Bore 5.4 in 11 in 11 in 11 in 11 in 6.89 in 6.69 in
Stroke 6 in 11.8 in 11.8 in 11.8 in 11.8 in 8.66 in 8.46 in
Displacement 1648.86 in³ 9064 in³ 18032 in³ 13524 in³ 13524 in³ 6456.31 in³ 4765 in³
Compression Ratio 13:01 13:01 13:01 13:01 13:01 15.3:1 14.0:1
Aspiration Turbocharged, Air to Air Aftercooled TA TA TA TA Turbo Aftercooled ATAAC
Fuel System Pump and Lines Direct unit injection Direct unit injection Direct unit injection Direct unit injection Common Rail Electronic Unit Injection
Governor Type ADEM™ A5 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) ADEM� A4 Adem™ A5

Generator Set Dimensions

Length - Maximum 162.4 in 404 in 404 in 404 in 404 in 331.1 in 318.4 in
Width - Minimum 75 in - - - - 92 in 104 in
Width - Maximum 78.3 in 99.62 in 99.62 in 99.62 in 99.62 in 128.5 in 104 in
Height - Maximum 75 in 156.6 in 156.6 in 156.6 in 156.6 in 150.7 in 131.6 in
Dry Weight - Genset (minimum) 12039 lb - - - - 55100 lb 44930 lb
Dry Weight - Genset (maximum) 13030 lb 91050 lb 141840 lb 112690 lb 112690 lb 66200 lb 45651 lb
Length - Minimum - - - - - 262.5 in 313.4 in
Height - Minimum - - - - - 99.8 in 131.6 in
Add a Similar Product:
  • 3616 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C175-16 Tier 4 Final Add
  • 3516E Low Voltage Generator Set Add
  • C175-16 Generator Set Add
  • 3516E Low Voltage Generator Set Add