C2.2 | DE22E3 50Hz EU IIIA EMISSIONS COMPLIANT
3612 Generator Set (Medium Speed)
C280-16 Generator Set (Medium Speed)
C280-6 Generator Set (Medium Speed)
C280-12 Generator Set (Medium Speed)
3616 Generator Set (Medium Speed)
C175-16 Generator Set

Generator Set Specifications

Minimum Rating 20 kVA 4400 kVA 4400 ekW (60Hz), 5875 kVA (50Hz) 1650 ekW (60Hz), 2200 kVA (50Hz) 3300 ekW (60Hz), 4400 kVA (50Hz) 3150 ekW 4700 kVA 2500 ekW
Maximum Rating 22 kVA 4850 kVA 4840 ekW (60Hz), 6500 kVA (50Hz) 1820 ekW (60Hz), 2425 kVA (50Hz) 3640 ekW (60Hz), 4850 kVA (50Hz) 4000 ekW 7520 kVA 3365 ekW
Emissions/Fuel Strategy R96/EUIIIa Equivalent Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 IMO Tier 2 EPA Tier 4 Final, IMO Tier 2 Low Fuel, Tier 2 Low Fuel Consumption Low Fuel, Tier 2
Voltage 200 to 400 Volts - - - - 480 to 13800 Volts - 480 to 13800 Volts
Frequency 50 Hz 50 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 60 Hz 50 Hz 60 Hz
Duty Cycle Standby, Prime Prime, Continuous Prime, Continuous Prime, Continuous Prime, Continuous Standby, Mission Critical, Prime, Continuous Standby, Prime, Continuous Standby, Mission Critical, Prime, Continuous
Speed - 750 & 1000 rpm 900 / 1000 rpm 900 / 1000 rpm 900 / 1000 rpm 1800 rpm 720 & 1000 rpm 1800 RPM
Standby Rating - - - - - 4000 (no fan)/3900/3620(no fan)/3500 ekW - 3365(no fan)/3250/3100(no fan)/3000 ekW
Prime Power Rating - - - - - 3600 (no fan)/3500/3300 (no fan)/3180 ekW - 3115(no fan)/3000/2825(no fan)/2725 ekW

Engine Specifications

Engine Model - 3612 V-12,4-Stroke Water-Cooled Diesel C280-16, V-16,4-Stroke Water-Cooled Diesel C280-6, I-6,4-Stroke Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Bore - 11 in 11 in 11 in 11 in 6.89 in 11 in 6.89 in
Stroke - 11.8 in 11.8 in 11.8 in 11.8 in 8.66 in 11.8 in 8.66 in
Displacement - 13524 in³ 18032 in³ 111 in³ 13524 in³ 6456.31 in³ 18032 in³ 6456.31 in³
Compression Ratio - 13:01 13:01 13:01 13:01 15.3:1 13:01 16.7:1
Aspiration - TA TA TA TA Turbo Aftercooled TA Turbo Aftercooled
Fuel System - Direct unit injection Direct unit injection Direct unit injection Direct unit injection Common Rail Direct unit injection Common Rail
Governor Type - Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) ADEM� A4 Generator Set Monitoring System (GMS) ADEM� A4

Generator Set Dimensions

Length - Maximum - 404 in 404 in 404 in 404 in 331.1 in 404 in 330.6 in
Width - Maximum - 99.62 in 99.62 in 99.62 in 99.62 in 128.5 in 99.62 in 124.3 in
Height - Maximum - 156.6 in 156.6 in 156.6 in 156.6 in 150.7 in 156.6 in 134.2 in
Dry Weight - Genset (maximum) - 112690 lb 141840 lb 74970 lb 112690 lb 66200 lb 141840 lb 57774 lb
Length - Minimum - - - - - 262.5 in - 250.9 in
Width - Minimum - - - - - 92 in - 82.7 in
Height - Minimum - - - - - 99.8 in - 86.9 in
Dry Weight - Genset (minimum) - - - - - 55100 lb - 42750 lb
Add a Similar Product:
  • 3612 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C175-16 Tier 4 Final Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Generator Set Add
  • 3516E Generator Set Add