Compare Equipment Go Back

3512B Diesel Generator Set
3516E Low Voltage Generator Set
3612 Generator Set (Medium Speed)
C280-12 Generator Set (Medium Speed)
C280-6 Generator Set (Medium Speed)
3616 Generator Set (Medium Speed)
C280-16 Generator Set (Medium Speed)

Generator Set Specifications

Standby Rating 1875/1750 kVA 2750 ekW - - - - -
Prime Power Rating 1700/1600 kVA 2500 ekW - - - - -
Emissions/Fuel Strategy Low Fuel , Low Emissions Tier 2, Low NOx Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 IMO Tier 2 Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2
Voltage 400 to 415 Volts 416 to 13,800 Volts - - - - -
Frequency 50 Hz 60 Hz 50 Hz 50 / 60 Hz 50 / 60 Hz 50 Hz 50 / 60 Hz
Speed 1500 rpm 1800 rpm 750 & 1000 rpm 900 / 1000 rpm 900 / 1000 rpm 720 & 1000 rpm 900 / 1000 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime Prime, Continuous Prime, Continuous Prime, Continuous Standby, Prime, Continuous Prime, Continuous
Minimum Rating 1600 kVA 2500 ekW 4400 kVA 3300 ekW (60Hz), 4400 kVA (50Hz) 1650 ekW (60Hz), 2200 kVA (50Hz) 4700 kVA 4400 ekW (60Hz), 5875 kVA (50Hz)
Maximum Rating 1875 kVA 2750 ekW 4850 kVA 3640 ekW (60Hz), 4850 kVA (50Hz) 1820 ekW (60Hz), 2425 kVA (50Hz) 7520 kVA 4840 ekW (60Hz), 6500 kVA (50Hz)

Engine Specifications

Engine Model 3512B TA, V-12, 4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke, Water-Cooled Diesel 3612 V-12,4-Stroke Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel C280-6, I-6,4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel C280-16, V-16,4-Stroke Water-Cooled Diesel
Bore 6.69 in 6.69 in 11 in 11 in 11 in 11 in 11 in
Stroke 7.48 in 8.47 in 11.8 in 11.8 in 11.8 in 11.8 in 11.8 in
Stroke - HD 8.46 in - - - - - -
Displacement 3161.03 in³ 4765 in³ 13524 in³ 13524 in³ 111 in³ 18032 in³ 18032 in³
Displacement - HD 3576 in³ - - - - - -
Compression Ratio 15.5:1 HD 14.7:1 13:01 13:01 13:01 13:01 13:01
Aspiration TA ATAAC TA TA TA TA TA
Fuel System Electronic Unit Injection EUI Direct unit injection Direct unit injection Direct unit injection Direct unit injection Direct unit injection
Governor Type ADEM™ A3 Adem™ A5 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Minimum 212.8 in - - - - - -
Length - Maximum 217.1 in 311.9 in 404 in 404 in 404 in 404 in 404 in
Width - Minimum 90 in - - - - - -
Width - Maximum 90 in 104 in 99.62 in 99.62 in 99.62 in 99.62 in 99.62 in
Height - Minimum 94.9 in - - - - - -
Height - Maximum 94.9 in 131.6 in 156.6 in 156.6 in 156.6 in 156.6 in 156.6 in
Dry Weight - Genset (minimum) 25620 lb - - - - - -
Dry Weight - Genset (maximum) 26530 lb 40750 lb 112690 lb 112690 lb 74970 lb 141840 lb 141840 lb
Add a Similar Product:
  • 3612 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C175-20 Add
  • 3606 Generator Set (Medium Speed) Add
  • C175-16 Tier 4 Final Add
  • C175-16 Generator Set Add
  • 3516E Generator Set Add
  • 3516E Low Voltage Generator Set Add