Net power is tested per ISO 9249:2007 and SAE J1349:2011 and as advertised is the power available at the flywheel when the engine is equipped with fan, air intake system, exhaust system and alternator.
Net power advertised is the power available at the engine flywheel when the engine is equipped with a fan, air cleaner, clean emissions module, and alternator.
-
Note (2)
All non-road U.S. EPA Tier 4 Final, EU Stage V, Japan 2014 (Tier 4 Final) and Korea Tier 4 Final diesel engines are required to use only Ultra Low Sulfur Diesel (ULSD) fuels containing 15 ppm EPA/10 ppm EU (mg/kg) sulfur or less.
-
-
Net Power - SAE J1349:2011
-
249 hp
-
Net Power - ISO 9249:2007
-
249 hp
-
Gross Power - SAE J1995:2014
-
286 hp
-
Engine Power - ISO 14396:2002
-
275 hp
-
Rated Speed
-
2200 r/min
-
Emissions
-
Option 2 - Brazil MAR-1, emitting equivalent to U.S. EPA Tier 3/EU Stage IIIA
-
Peak Torque (1400 rpm)
-
902 lbf·ft
-
Torque Rise
-
26 %
-
Engine Power - ISO 14396: 2002
-
275 hp
-
Peak Torque ( 1,400 rpm )
-
749 lbf·ft
-
Bore
-
4.1 in
-
Stroke
-
5.3 in
-
High Idle Speed
-
2270 r/min
-
Low Idle Speed
-
800 r/min
-
Maximum Altitude without Derating
-
9842.5 ft
-
Weights
Operating Weight
20640 lb
-
-
Operating Weight - LGP
21369 lb
-
-
Operating Weight - LGP, 762 mm/30 in
21810 lb
-
-
Note (2)
For machine with ripper, add 554 kg (1,222 lb).
-
-
Note (1)
Specifications shown are for machine equipped with dozer blade, EROPS cab, back-up alarm, operator, coolant, lubricants and full fuel tank.
-
-
Transmission
Drive Pumps
1
-
-
Maximum Travel Speed - Forward
5.6 mile/h
-
-
Maximum Travel Speed - Reverse
6.2 mile/h
-
-
Track Motors
2
-
-
Relief Valve Settings
7033 psi
-
-
Transmission Type
-
Cat Planetary Power Shift
-
Forward - 1
-
3.7 mile/h
-
Forward - 2
-
6.5 mile/h
-
Forward - 3
-
11.2 mile/h
-
Forward - 4
-
19.4 mile/h
-
Reverse - 1
-
4.2 mile/h
-
Reverse - 2
-
7.3 mile/h
-
Reverse - 3
-
12.8 mile/h
-
Reverse - 4
-
22.1 mile/h
-
Hydraulic Controls
Pump Output
17.2 gal/min
-
-
Relief Valve Settings
2988 psi
-
-
Ripper
Type
Parallelogram
-
-
Number of Shanks
3
-
-
Height
6.5 in
-
-
Weight
1222 lb
-
-
Maximum Digging Depth
13.3 in
-
-
Maximum Reach - Ground Line
30.2 in
-
-
Overall Width
67.3 in
-
-
Maximum Ground Clearance Under Tip
17.6 in
-
-
Undercarriage
Ground Pressure - LGP
4.5 psi
-
-
Track Gauge - LGP
69 in
-
-
Length - Track on Ground - LGP
91 in
-
-
Number of Shoes - Each Side - Sealed and Lubricated Track (SALT) Undercarriage
40
-
-
Ground Pressure - LGP, 762 mm (30 in)
3.9 psi
-
-
Length - Track on Ground - LGP, 762 mm (30 in)
91 in
-
-
Shoe Width - LGP
26 in
-
-
Shoe Width - LGP, 762 mm (30 in)
30 in
-
-
Track Gauge
63 in
-
-
Number of Rollers - Each Side
7
-
-
Track Gauge - LGP, 762 mm (30 in)
73 in
-
-
Shoe Width - Standard
20 in
-
-
Undercarriage
Ground Pressure
5.7 psi
-
-
Length of Track on Ground
91 in
-
-
Number of Shoes - Each Side - Abrasion Undercarriage
36
-
-
Service Refill Capacities
Cooling System
5 gal (US)
-
-
Final Drive - Each - LGP
2.6 gal (US)
-
-
Crankcase - With Filter
2.8 gal (US)
-
-
Transmission - Hydraulic Tank
23.8 gal (US)
-
-
Fuel Tank
51.5 gal (US)
132.1 gal (US)
-
Diesel Exhaust Fluid (DEF) Tank
4.9 gal (US)
-
-
Diesel Exhaust Fluid Tank
-
4.2 gal (US)
-
Cooling Systems - Tier 4 Final/EU Stage V
-
21.4 gal (US)
-
Cooling Systems - Tier 3/Stage IIIA equivalent
-
19.3 gal (US)
-
Engine Crankcase
-
5.3 gal (US)
-
Transmission
-
13.2 gal (US)
-
Differential - Final Drives - Front
-
17.2 gal (US)
-
Differential - Final Drives - Rear
-
17.2 gal (US)
-
Hydraulic System - Implement/Steering
-
34.1 gal (US)
-
Hydraulic Tank Only
-
19.8 gal (US)
-
Note (1)
-
All nonroad Tier 4 Final and EU Stage V diesel engines are required to use: – Ultra low sulfur diesel (ULSD) fuels containing 15 ppm (mg/kg) sulfur or less. – Cat engines are compatible with the following renewable, alternative, and biodiesel* fuels that
-
Service Refill Capacities
Final Drives - Each Side
2.6 gal (US)
-
-
Air Conditioning System
Air Conditioning
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a (Global Warming Potential = 1430). The system contains 1.8 kg of refrigerant which has a CO2 equivalent of 2.574 metric tonnes.
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system con
-
Dimensions
BLADE: Blade Width - LGP
126.7 in
-
-
Track Gauge - LGP, 762 mm (30 in)
73 in
-
-
BLADE: Digging Depth - LGP
23.2 in
-
-
Track Gauge - LGP
67.9 in
-
-
BLADE: Blade Capacity (SAE) - LGP
3.06 yd³
-
-
BLADE: Blade Width at Maximum Angle - LGP
115.8 in
-
-
BLADE: Blade Cutting Edge Angle, Adjustable - LGP
52° to 58°
-
-
Ground Clearance - LGP, 762 mm (30 in)
13 in
-
-
BLADE: Blade Height - LGP
39.8 in
-
-
BLADE: Blade Lift Height - LGP
30.2 in
-
-
Ground Clearance - LGP
13 in
-
-
Overall Length - With Blade - LGP, 762 mm (30 in)
169.6 in
-
-
Overall Length - With Blade - LGP
169.6 in
-
-
Note
With Ripper Attachment (add to Length of Basic Dozer) - 1177 mm (46.3 in)
-
-
BLADE: Maximum Tilt - LGP
17.7 in
-
-
BLADE: Maximum Angle (either side) - LGP
25°
-
-
Length of Basic Dozer (without blade) - Standard
128.7 in
-
-
Dozer Height - Standard
109 in
-
-
Width of Dozer (standard shoes, no blade) - LGP
94.9 in
-
-
Width of Dozer (standard shoes, no blade) - LGP, 762 mm (30 in)
103.5 in
-
-
Length of Basic Dozer (without blade) - LGP
128.7 in
-
-
Dozer Height - LGP, 762 mm (30 in)
109 in
-
-
Width of Dozer (standard shoes, no blade) - Standard
83 in
-
-
Length of Basic Dozer (without blade) - LGP, 762 mm (30 in)
128.7 in
-
-
Dozer Height - LGP
109 in
-
-
Dimensions
BLADE: Blade Capacity (SAE) - Standard
2.86 yd³
-
-
Track Gauge - Standard
63 in
-
-
BLADE: Digging Depth - Standard
23.8 in
-
-
BLADE: Blade Lift Height - Standard
30.2 in
-
-
Ground Clearance - Standard
13 in
-
-
Overall Length - With Blade - Standard
170.7 in
-
-
BLADE: Blade Cutting Edge Angle, Adjustable - Standard
52° to 58°
-
-
BLADE: Blade Height - Standard
42.2 in
-
-
BLADE: Maximum Tilt - Standard
15.8 in
-
-
Note
Abrasion Undercarriage
-
-
BLADE: Blade Width - Standard
109.5 in
-
-
BLADE: Blade Width at Maximum Angle - Standard
103.8 in
-
-
BLADE: Maximum Angle (either side) - Standard
25°
-
-
Engine
Power Train
Hydrostatic
-
-
Cab
ROPS
ISO 3471:2008
-
-
FOPS
ISO 3449:2005 Level II
-
-
Retrieval Winch
Maximum Line Pull - Bare Drum
32150 lb
-
-
Control
Hydraulic
-
-
Rope Diameter - Optional
0.75 in
-
-
Drum Capacity - Optional Cable
195 ft
-
-
Maximum Line Speed - Full Drum
79 ft/min
-
-
Drum Capacity - Recommended Cable
277 ft
-
-
Winch Drive
Hydraulic
-
-
Weight
1747 lb
-
-
Maximum Line Pull - Full Drum
20350 lb
-
-
Rope Diameter - Recommended
0.63 in
-
-
Maximum Line Speed - Bare Drum
50 ft/min
-
-
Speed
Variable
-
-
Winch Length
35.63 in
-
-
Drum Diameter
8 in
-
-
Overall width
27.91 in
-
-
Drum Width
9.65 in
-
-
Throat Clearance
5.6 in
-
-
High Performance Winch
Winch length
27.76 in
-
-
Rope diameter – optional
0.75 in
-
-
Maximum line speed – bare drum
131 ft/min
-
-
Maximum line pull – bare drum
40000 lb
-
-
Weight
1345 lb
-
-
Drum capacity – optional
256 ft
-
-
Maximum line speed – full drum
207 ft/min
-
-
Rope diameter – recommended
0.63 in
-
-
Winch drive
Hydrostatic
-
-
Throat clearance
6.75 in
-
-
Drum diameter
10 in
-
-
Overall width
29.2 in
-
-
Drum width
10.8 in
-
-
Maximum line pull – full drum
25000 lb
-
-
Speed
Variable
-
-
Drum capacity – recommended cable
371 ft
-
-
Control
Hydraulic
-
-
Operating Specifications
Operating Weight (Tier 4 Final/Stage V)
-
48526 lb
-
Operating Weight (Tier 3/Stage IIIA equivalent)
-
47887 lb
-
Hydraulic System - Lift/Tilt
Lift/Tilt System - Circuit
-
Pilot operated load sensing valve with EH
-
Lift/Tilt System
-
Variable displacement piston
-
Maximum Flow at 2,200 rpm
-
23.5 gal/min
-
Relief Valve Setting - Lift/Tilt
-
3190 psi
-
Cylinders, Double Acting - Lift, Bore and Stroke
-
120 mm × 915 mm (4.7 in × 36.0 in)
-
Cylinders, Double Acting - Left and Right Tilt, Bore and Stroke
-
101.6 mm × 234 mm (4.0 in × 9.2 in)
-
Pilot System
-
Open center, fixed displacement gear
-
Pilot Relief Valve Setting
-
3046 psi
-
Hydraulic System - Steering
Steering System - Circuit
-
Pilot, load sensing
-
Steering System - Pump
-
Variable displacement piston
-
Maximum Flow at 2,200 rpm
-
38.8 gal/min
-
Relief Valve Setting - Steering
-
4003 psi
-
Total Steering Angle
-
72°
-
Steering Cycle Times - High Idle
-
3 s
-
Steering Cycle Times - Low Idle
-
8.2 s
-
Axles
Front
-
Planetary – Fixed
-
Rear
-
Planetary – Oscillating
-
Oscillation Angle
-
±10°
-
Braking System
Service Brakes
-
Single Disc Wet (enclosed) 4 WHL
-
Parking Brake
-
Drum and Shoe, Spring Applied, Hydraulic Released
-
Sound Performance - Tier 4 Final / Stage V
Operator Sound Pressure Level (ISO 6396:2008)
-
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
-
111 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
-
70 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)*
-
109 dB(A)
-
Note (1)
-
* Sound suppression equipped
-
Note (2)
-
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at maximum engine cooling fan speed.
-
Note (3)
-
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at maximum engine cooling fan speed.
-
Note (4)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Sound Performance - Tier 3 / Stage IIIA
Operator Sound Pressure Level (ISO 6396:2008)
-
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
-
112 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
-
70 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)*
-
110 dB(A)
-
Note (1)
-
* Sound suppression equipped
-
Note (2)
-
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at maximum engine cooling fan speed.
-
Note (3)
-
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at maximum engine cooling fan speed.
-
Note (4)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.