Compare Equipment Go Back

DG125 (Single-phase and 3 phase) (60 Hz)
Cat Customizable Switchgear and Controls
D250 GC (60 Hz) Generator Set

Generator Set Specifications

Frequency 60 Hz - 60 Hz
Gas Standby Rating 125 ekW - -
Emissions/Fuel Strategy U.S. EPA Certified for Stationary Emergency and Non-Emergency Application - EPA Stationary Emergency
Voltage 208-600 - 208 to 600 Volts
Speed 1800 rpm - 1800 rpm
Natural Gas Rating 125 ekW - -
Maximum Rating - - 250 ekW
Minimum Rating - - 250 ekW
Duty Cycle - - Standby

Engine Specifications

Engine Model V8, 6.2L TCAC - Cat® C9 In-line 6, 4-cycle Diesel
Bore 4 in - 4.4 in
Stroke 3.75 in - 5.9 in
Displacement 378.3 in³ - 538 in³
Compression Ratio 9.8:1 - 16.3:1
Aspiration TCAC - Turbocharged Air-to-Air Aftercooled
Fuel System Electronic - HEUI
Governor Type - - Adem™A4

Generator Set Dimensions

Length 96 in - -
Width 51 in - -
Height 57 in - -
Dry Weight - Genset 3226 lb - -
Length - Maximum - - 155.5 in
Width - Minimum - - 56.3 in
Width - Maximum - - 56.7 in
Height - Minimum - - 67.2 in
Height - Maximum - - 86.7 in
Dry Weight - Genset (minimum) - - 5324.2 lb
Dry Weight - Genset (maximum) - - 6735.1 lb

Technical Summary

Configuration - Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc -
Modes of Operation - All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow -
Application - LV and MV ( 208V - 38 kV) 50 / 60 Hz -

Generator Protective Devices

ANSI Protective Devices - Per customer specification -

Utility Protective Devices

ANSI Protective Devices - Per customer specification -

Environmental Parameters

Certifications - Per customer specification -
Control Panel Enclosure - Per customer specification -
Operating Temperature - Per customer specification -
Storage Temperature - Per customer specification -
Low Voltage Standards - Per customer specification -
Medium Voltage Standards - Per customer specification -
Add a Similar Product:
  • Cat Switchgear Add
  • Cat XLM Switchgear Add
  • Cat EGP Switchgear Add
  • EMCP 4.4 Master Control Panel Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • Energy Capacity Expansion (ECE) module Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • Energy Time Shift (ETS) Module Add
  • XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
  • Temporary Connection Boxes Add