DG100 (60 Hz)
Cat XLM Switchgear
Cat Switchgear
XQP550 EU Stage V

Generator Set Specifications

Frequency 60 Hz - - -
Gas Standby Rating 100 ekW - - -
Emissions/Fuel Strategy U.S. EPA Certified for Stationary Emergency Application - - -
Speed 1800 rpm - - -
Voltage 208-600 - - -

Engine Specifications

Engine Model V8, 6.2L TCAC - - -
Stroke 3.75 in - - -
Displacement 378.3 in³ - - -
Compression Ratio 9.8:1 - - -
Aspiration TCAC - - -
Bore 4 in - - -
Fuel System Electronic - - -

Generator Set Dimensions

Length 96 in - - -
Width 51 in - - -
Height 57 in - - -
Dry Weight - Genset 3007 lb - - -

Technical Summary

Configuration - Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications - -
Modes of Operation - Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power - -
Application - LV and MV ( 208V - 38 kV - -
Technical Summary - - Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers. -

Generator Protective Devices

ANSI Protective Devices - 15/25, 27/59, 81 O/U, 32, 40, 50, 51 - -

Utility Protective Devices

ANSI Protective Devices - 15/25, 27/59, 81 O/U, 32, 40, 47, 50, 51, 86 - -

Environmental Parameters

Certifications - IBS, CBC, UBC & OSHPD Certified - -
Control Panel Enclosure - NEMA 1 or NEMA 3R, Freestanding Construction - -
Operating Temperature - 0 degrees to 50 degrees C - -
Storage Temperature - -20 degrees C to +60 degrees C - -
Low Voltage Standards - NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 - -
Medium Voltage Standards - NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 - -

Enclosure Rating

Configuration - - IP4X -

Operating Temperature

Operating Temperature - - 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F) -

Dimensions

Standard Widths - - 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A. -
Standard Heights - - Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping -
Standard Depths - - 300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers -
Width - - - 80.3 in
Height - - - 90.5 in
Length - - - 213.3 in
Weight - With Lube Oil and Coolant - - - 14860 lb

Application

Application - - LV 380…480 VAC, 50 Hz, 3-Phase. -

Modes of Operation

Modes of Operation - - Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc. -

Generator Set

Rating Prime - - - 550 kVA
Frequency - - - 50/60 Hz
Voltage - - - 220 - 480 V
Fuel/Emissions Strategy - - - EU Stage V

Engine

Engine - - - Cat® C18
Fuel - - - Diesel

Fuel Consumption

100% Load 60 Hz - - - 129.7 gal/hr
100% Load 50 Hz - - - 18.7 gal/hr
75% Load 60 Hz - - - 0 gal/hr
75% Load 50 Hz - - - 23.1 gal/hr

Noise rating (with enclosure)

Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz) - - - 79.19
Add a Similar Product:
  • Cat Customizable Switchgear and Controls Add
  • EMCP 4.4 Master Control Panel Add
  • Cat EGP Switchgear Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • Energy Capacity Expansion (ECE) module Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • Temporary Connection Boxes Add
  • Energy Time Shift (ETS) Module Add
  • XQ425 Add