Hydraulic System - Steering and Engine Cooling Fan - Tank Only
77 gal (US)
-
-
Note (1)
- All nonroad U.S. EPA Tier 4, European Union (EU) Stage IIIB and V, and Japan (MLIT) Step 4 diesel engines are required to use only Ultra Low Sulfer Diesel (ULSD) fuels containing 15 ppm (mg/kg) sulfer or less. Biodiesel blends up to B20 (20% blend by vo
-
-
Hydraulic System - Implement and Hydraulic Fan
-
68.9 gal (US)
-
Hydraulic System - Steering and Braking
-
34.9 gal (US)
-
Axles
Front
Fixed
Fixed
-
Rear
Trunnion
Trunnion
-
Oscillation Angle
-
8.5 °
-
Brakes
Brakes
Meets ISO 3540:2011
Meets ISO 3540:2011
-
Blades
Blade Capacities
30.5 to 44.8 m3 (40 to 58.6 yd3)
-
-
Dimensions (Approximate)
Height - Top of ROPS
18.25 ft
17.2 ft
-
Height - Top of Exhaust Pipe
17.17 ft
16.6 ft
-
Height - Top of Hood
13 ft
12.7 ft
-
Ground Clearance
27 in
2 ft
-
Centerline of Front Axle to Hitch
9.67 ft
7.5 ft
-
Centerline of Rear Axle to Edge of Bumper
13.75 ft
12.5 ft
-
Wheel Base
19.25 ft
15.1 ft
-
Length - With Blade on Ground
44 ft
36.5 ft
-
Hydraulic System - Steering
Steering System - Pump
Piston, variable displacement
Piston, variable displacement
-
Minimum Turning Radius - Over Blade
31 ft
34 ft
-
Steering System - Circuit
Pilot, load sensing
Pilot, load sensing
-
Total Steering Angle
86 degrees
35 °
-
Relief Valve Setting
5004 psi
4500 psi
-
Maximum Flow
-
94.3 gal/min
-
Operating Specifications
Operating Weight
224647 lb
165089 lb
-
Blade Capacities
-
15.9 - 30.7 m3 (20.7 - 40.2 yd3)
-
Sound Performance Levels
Sound Performance
• The machine sound power level was measured according to
ISO 6395:2008. The measurement was conducted at 70 percent
of the maximum engine cooling fan speed.
• The operator sound pressure level was measured according to
ISO 6396:2008. The measurement was
-
-
Air Conditioning System
Air Conditioning
The air conditioning system on this machine contains the fluorinated
greenhouse gas refrigerant R134a (Global Warming Potential = 1430).
The system contains 1.8 kg of refrigerant which has a CO2 equivalent
of 2.574 metric tonnes.
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a (Global Warming Potential = 1430). The system contains 1.8 kg of refrigerant which has a CO2 equivalent of 2.574 metric tonnes.
-
Cab
ROPS/FOPS
ISO 3471:2008 and ISO 3449:2005 Level II Standards
ISO 3471:2008 and ISO 3449:2005 Level II Standards