Net power is tested per ISO 9249:2007 and SAE J1349:2011 and as advertised is the power available at the flywheel when the engine is equipped with fan, air intake system, exhaust system and alternator.
Net power advertised is the power available at the engine flywheel when the engine is equipped with a fan, air cleaner, clean emissions module, and alternator.
-
Note (2)
All non-road U.S. EPA Tier 4 Final, EU Stage V, Japan 2014 (Tier 4 Final) and Korea Tier 4 Final diesel engines are required to use only Ultra Low Sulfur Diesel (ULSD) fuels containing 15 ppm EPA/10 ppm EU (mg/kg) sulfur or less.
-
-
Net Power - SAE J1349:2011
-
249 hp
-
Net Power - ISO 9249:2007
-
249 hp
-
Gross Power - SAE J1995:2014
-
286 hp
-
Engine Power - ISO 14396:2002
-
275 hp
-
Rated Speed
-
2200 r/min
-
Emissions
-
Option 2 - Brazil MAR-1, emitting equivalent to U.S. EPA Tier 3/EU Stage IIIA
-
Peak Torque (1400 rpm)
-
902 lbf·ft
-
Torque Rise
-
26 %
-
Engine Power - ISO 14396: 2002
-
275 hp
-
Peak Torque ( 1,400 rpm )
-
749 lbf·ft
-
Bore
-
4.1 in
-
Stroke
-
5.3 in
-
High Idle Speed
-
2270 r/min
-
Low Idle Speed
-
800 r/min
-
Maximum Altitude without Derating
-
9842.5 ft
-
Weights
Operating Weight
17855 lb
-
-
Operating Weight - LGP
18839 lb
-
-
Note (1)
Specifications shown are for machine equipped with dozer blade, EROPS cab, back-up alarm, operator, coolant, lubricants and full fuel tank.
-
-
Operating Weight - LGP, 762 mm/30 in
19295 lb
-
-
Note (2)
For machine with ripper, add 554 kg (1,222 lb).
-
-
Transmission
Drive Pumps
1
-
-
Maximum Travel Speed - Reverse
6.2 mile/h
-
-
Relief Valve Settings
7033 psi
-
-
Maximum Travel Speed - Forward
5.6 mile/h
-
-
Track Motors
2
-
-
Transmission Type
-
Cat Planetary Power Shift
-
Forward - 1
-
3.7 mile/h
-
Forward - 2
-
6.5 mile/h
-
Forward - 3
-
11.2 mile/h
-
Forward - 4
-
19.4 mile/h
-
Reverse - 1
-
4.2 mile/h
-
Reverse - 2
-
7.3 mile/h
-
Reverse - 3
-
12.8 mile/h
-
Reverse - 4
-
22.1 mile/h
-
Hydraulic Controls
Pump Output
17.2 gpm
-
-
Relief Valve Settings
2988 psi
-
-
Ripper
Type
Parallelogram
-
-
Number of Shanks
3
-
-
Height
6.5 in
-
-
Weight
1222 lb
-
-
Maximum Ground Clearance Under Tip
17.6 in
-
-
Maximum Digging Depth
13.3 in
-
-
Overall Width
67.3 in
-
-
Maximum Reach - Ground Line
30.2 in
-
-
Engine
Power Train
Hydrostatic
-
-
Cab
FOPS
ISO 3449:2005 Level II
-
-
ROPS
ISO 3471:2008
-
-
Undercarriage
Length - Track on Ground - LGP, 762 mm (30 in)
89 in
-
-
Length - Track on Ground - LGP
89 in
-
-
Track Gauge - LGP
68 in
-
-
Shoe Width - LGP, 762 mm (30 in)
30 in
-
-
Track Gauge - LGP, 762 mm (30 in)
73 in
-
-
Shoe Width - LGP
25 in
-
-
Track Gauge
59 in
-
-
Shoe Width - Standard
16 in
-
-
Ground Pressure - LGP
4.3 psi
-
-
Ground Pressure - LGP, 762 mm (30 in)
3.7 psi
-
-
Number of Shoes - Each Side - Sealed and Lubricated Track (SALT) Undercarriage
43
-
-
Number of Rollers - Each Side
6
-
-
Undercarriage
Length of Track on Ground
89 in
-
-
Number of Shoes - Each Side - Abrasion Undercarriage
38
-
-
Ground Pressure
6.45 psi
-
-
Service Refill Capacities
Final Drive - Each - LGP
2.6 gal (US)
-
-
Cooling System
4.2 gal (US)
-
-
Diesel Exhaust Fluid (DEF) Tank
4.9 gal (US)
-
-
Transmission - Hydraulic Tank
23.8 gal (US)
-
-
Crankcase - With Filter
2.8 gal (US)
-
-
Fuel Tank
51.5 gal (US)
132.1 gal (US)
-
Diesel Exhaust Fluid Tank
-
4.2 gal (US)
-
Cooling Systems - Tier 4 Final/EU Stage V
-
21.4 gal (US)
-
Cooling Systems - Tier 3/Stage IIIA equivalent
-
19.3 gal (US)
-
Engine Crankcase
-
5.3 gal (US)
-
Transmission
-
13.2 gal (US)
-
Differential - Final Drives - Front
-
17.2 gal (US)
-
Differential - Final Drives - Rear
-
17.2 gal (US)
-
Hydraulic System - Implement/Steering
-
34.1 gal (US)
-
Hydraulic Tank Only
-
19.8 gal (US)
-
Note (1)
-
All nonroad Tier 4 Final and EU Stage V diesel engines are required to use: – Ultra low sulfur diesel (ULSD) fuels containing 15 ppm (mg/kg) sulfur or less. – Cat engines are compatible with the following renewable, alternative, and biodiesel* fuels that
-
Service Refill Capacities
Final Drives - Each Side
2.6 gal (US)
-
-
Air Conditioning System
Air Conditioning
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a (Global Warming Potential = 1430). The system contains 1.8 kg of refrigerant which has a CO2 equivalent of 2.574 metric tonnes.
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system con
-
Dimensions
BLADE: Blade Capacity (SAE) - LGP
2.17 yd³
-
-
BLADE: Blade Lift Height - LGP
28.7 in
-
-
BLADE: Maximum Tilt - LGP
17.2 in
-
-
BLADE: Blade Width - LGP
124 in
-
-
Ground Clearance - LGP
13 in
-
-
BLADE: Blade Width at Maximum Angle - LGP
113.1 in
-
-
BLADE: Digging Depth - LGP
23 in
-
-
Track Gauge - LGP
67.9 in
-
-
Ground Clearance - LGP, 762 mm (30 in)
13 in
-
-
BLADE: Blade Height - LGP
33.8 in
-
-
Overall Length - With Blade - LGP, 762 mm (30 in)
167.8 in
-
-
Track Gauge - LGP, 762 mm (30 in)
73 in
-
-
BLADE: Blade Cutting Edge Angle, Adjustable - LGP
52° to 58°
-
-
BLADE: Maximum Angle (either side) - LGP
25°
-
-
Overall Length - With Blade - LGP
167.8 in
-
-
Note
*Abrasion Undercarriage
-
-
Length of Basic Dozer (without blade) - LGP, 762 mm (30 in)
129.6 in
-
-
Width of Dozer (standard shoes, no blade) - Standard
74.8 in
-
-
Length of Basic Dozer (without blade) - Standard
129.6 in
-
-
Length of Basic Dozer (without blade) - LGP
129.6 in
-
-
Width of Dozer (standard shoes, no blade) - LGP, 762 mm (30 in)
94.9 in
-
-
Dozer Height - LGP
108.9 in
-
-
Width of Dozer (standard shoes, no blade) - LGP
92.9 in
-
-
Dozer Height - LGP, 762 mm (30 in)
108.9 in
-
-
Dozer Height - Standard
108.9 in
-
-
Dimensions
Note
With Ripper Attachment (add to Length of Basic Dozer) - 1177 mm (46.3 in)
-
-
BLADE: Blade Width at Maximum Angle - Standard
95.2 in
-
-
BLADE: Digging Depth - Standard
23.2 in
-
-
BLADE: Blade Width - Standard
104.2 in
-
-
BLADE: Blade Lift Height - Standard
28.7 in
-
-
Ground Clearance - Standard
13 in
-
-
BLADE: Blade Cutting Edge Angle, Adjustable - Standard
52° to 58°
-
-
BLADE: Maximum Angle (either side) - Standard
25°
-
-
BLADE: Maximum Tilt - Standard
14.5 in
-
-
BLADE: Blade Capacity (SAE) - Standard
1.99 yd³
-
-
Track Gauge - Standard
58.9 in
-
-
BLADE: Blade Height - Standard
35.8 in
-
-
Overall Length - With Blade - Standard
168 in
-
-
High Performance Winch
Weight
1345 lb
-
-
Drum diameter
10 in
-
-
Winch drive
Hydrostatic
-
-
Winch length
27.76 in
-
-
Maximum line pull – bare drum
40000 lb
-
-
Maximum line speed – full drum
207 ft/min
-
-
Drum width
10.8 in
-
-
Drum capacity – optional
256 ft
-
-
Rope diameter – recommended
0.63 in
-
-
Maximum line pull – full drum
25000 lb
-
-
Rope diameter – optional
0.75 in
-
-
Speed
Variable
-
-
Maximum line speed – bare drum
131 ft/min
-
-
Throat clearance
6.75 in
-
-
Drum capacity – recommended cable
371 ft
-
-
Overall width
29.2 in
-
-
Control
Hydraulic
-
-
Retrieval Winch
Drum Diameter
8 in
-
-
Drum Width
9.65 in
-
-
Throat Clearance
5.6 in
-
-
Winch Length
35.63 in
-
-
Overall width
27.91 in
-
-
Weight
1747 lb
-
-
Maximum Line Pull - Full Drum
79 ft/min
-
-
Drum Capacity - Recommended Cable
277 ft
-
-
Maximum Line Pull - Bare Drum
50 ft/min
-
-
Drum Capacity - Optional Cable
195 ft
-
-
Maximum Line Speed - Full Drum
20350 lb
-
-
Control
Hydraulic
-
-
Maximum Line Speed - Bare Drum
32150 lb
-
-
Rope Diameter - Optional
0.75 in
-
-
Winch Drive
Hydraulic
-
-
Rope Diameter - Recommended
0.63 in
-
-
Speed
Variable
-
-
Operating Specifications
Operating Weight (Tier 4 Final/Stage V)
-
48526 lb
-
Operating Weight (Tier 3/Stage IIIA equivalent)
-
47887 lb
-
Hydraulic System - Lift/Tilt
Lift/Tilt System - Circuit
-
Pilot operated load sensing valve with EH
-
Lift/Tilt System
-
Variable displacement piston
-
Maximum Flow at 2,200 rpm
-
23.5 gpm
-
Relief Valve Setting - Lift/Tilt
-
3190 psi
-
Cylinders, Double Acting - Lift, Bore and Stroke
-
120 mm × 915 mm (4.7 in × 36.0 in)
-
Cylinders, Double Acting - Left and Right Tilt, Bore and Stroke
-
101.6 mm × 234 mm (4.0 in × 9.2 in)
-
Pilot System
-
Open center, fixed displacement gear
-
Pilot Relief Valve Setting
-
3046 psi
-
Hydraulic System - Steering
Steering System - Circuit
-
Pilot, load sensing
-
Steering System - Pump
-
Variable displacement piston
-
Maximum Flow at 2,200 rpm
-
38.8 gpm
-
Relief Valve Setting - Steering
-
4003 psi
-
Total Steering Angle
-
72°
-
Steering Cycle Times - High Idle
-
3 s
-
Steering Cycle Times - Low Idle
-
8.2 s
-
Axles
Front
-
Planetary – Fixed
-
Rear
-
Planetary – Oscillating
-
Oscillation Angle
-
±10°
-
Braking System
Service Brakes
-
Single Disc Wet (enclosed) 4 WHL
-
Parking Brake
-
Drum and Shoe, Spring Applied, Hydraulic Released
-
Sound Performance - Tier 4 Final / Stage V
Operator Sound Pressure Level (ISO 6396:2008)
-
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
-
111 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
-
70 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)*
-
109 dB(A)
-
Note (1)
-
* Sound suppression equipped
-
Note (2)
-
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at maximum engine cooling fan speed.
-
Note (3)
-
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at maximum engine cooling fan speed.
-
Note (4)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Sound Performance - Tier 3 / Stage IIIA
Operator Sound Pressure Level (ISO 6396:2008)
-
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
-
112 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
-
70 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)*
-
110 dB(A)
-
Note (1)
-
* Sound suppression equipped
-
Note (2)
-
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at maximum engine cooling fan speed.
-
Note (3)
-
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at maximum engine cooling fan speed.
-
Note (4)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.