Generator Set Specifications
  • Minimum Rating - 50 ekW
  • Maximum Rating - 50 ekW
  • Emissions/Fuel Strategy - Non Regulated
  • Voltage - 220 to 480 Volts
  • Frequency - 60 Hz
  • Speed - 1800 rpm
  • Duty Cycle - Standby
Engine Specifications
  • Engine Model - Cat® C3.3, In-line 3, 4-cycle diesel
  • Bore - 4.1in
  • Stroke - 5in
  • Displacement - 201.4in³
  • Compression Ratio - 17.25:1
  • Aspiration - Turbocharged
  • Fuel System - Inline
  • Governor Type - Mechanical
Generator Set Dimensions
  • Length - Maximum - 76.6in
  • Width - Maximum - 34.3in
  • Height - Maximum - 48.7in
  • Dry Weight - Genset (maximum) - 2114lb
Standard Equipment:
  • Engine
    • C3.3, Inline 3 Cylinder, 4 Stroke Diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical Governor
  • Alternator
    • A Frame Standard Alternator
  • Fuel Storage
    • Single Wall 8 Hour Tank
  • Enclosure
    • Cat GC Enclosure
  • Air, Cooling & Exhaust
    • Enclosure Silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance
  • Alternator Requirements
    • Space Heater
  • Auxiliary Supply Voltage
    • 120V
  • Fuel Storage
    • Dual Wall 8 Hour Tank
    • Low Fuel Level Shutdown
    • Single Wall Tank With Containment
    • Low Fuel Level Alarm
    • High Fuel Level Alarm
  • Genset Control
    • Battery Charger
    • Volt Free Contacts for Genset Running
    • Volt Free Contacts for Common Alarm
    • Emergency Stop with Key
    • Earth Leakage
    • USB to RS485 Communications Device
    • Earth Fault
    • Panel Mounted Audible Alarm
    • Battery
    • Standby Pack (Smart Jacket Water Heater, Battery Charger)
    • Coolant Heater
    • Low Coolant Level Shutdown
  • Circuit Breaker
    • 3 Pole Circuit Breaker 63A
    • 3 Pole Circuit Breaker 80A
    • 3 Pole Circuit Breaker 100A
    • 3 Pole Circuit Breaker 125A
    • 3 Pole Circuit Breaker 160A
    • 3 Pole Circuit Breaker 200A
    • 4 Pole Circuit Breaker 63A
    • 4 Pole Circuit Breaker 80A
    • 4 Pole Circuit Breaker 100A
    • 4 Pole Circuit Breaker 125A
    • 4 Pole Circuit Breaker 160A
    • 4 Pole Circuit Breaker 200A
    • Circuit Breaker Padlock
    • Neutral Earth Link
    • Overload via Alarm Switch on Breaker
  • Testing & Packaging
    • PGS Test Report @ 1.0PF
    • PGS Test Report @ 0.8PF