D40 GC Generator Set

Product description

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
  • Maximum Rating - 40 ekW
  • Minimum Rating - 40 ekW
  • Emissions/Fuel Strategy - U.S. EPA Cert., Tier 3, SCAQMD Compliant
  • Voltage - 208 to 600 Volts
  • Frequency - 60 Hz
  • Speed - 1800 rpm
  • Duty Cycle - Standby
Engine Specifications
  • Engine Model - C4.4, In-line 4, 4-cycle diesel
  • Bore - 4.1in
  • Stroke - 5in
  • Displacement - 269in
  • Compression Ratio - 18.2:1
  • Aspiration - Turbocharged
  • Fuel System - Common Rail
  • Governor Type - Mechanical, ADEM™A4
Generator Set Dimensions
  • Length - Maximum - 77.2in
  • Width - Maximum - 43.3in
  • Height - Maximum - 48in
  • Dry Weight - Genset (maximum) - 1847lb
Standard Equipment:
  • Certificates
    • IBC seismic and wind Certifications
  • Air Inlet System
    • Air cleaner
    • Cartridge type air filter
  • Circuit Breakers
    • Breakers (100% UL rated)
    • Second circuit breaker box
    • 3-Pole 100% rated
    • Power terminal strip
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Control Panel
    • GCCP 1.2 Control panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
  • Control Panels
    • NFPA110 bundle includes:
    • WSS1 Low coolant level shut down
    • WCA1 Low coolant temperature alarm
    • FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
    • PBC10NU NFPA battery charger
    • Oil temperature gauge and sender
    • A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
    • PAA1 Panel mounted audible alarm
    • Remote E-stop button
    • Volt free contacts genset run and common alarm
    • Discrete I/O module
    • Audible alarm
    • Ground fault relay
    • Remote annunciator module
    • Overload shutdown via breaker
    • Low coolant level shutdown
    • Fuel level reading
    • Protective devices:
    • Low coolant temperature alarm
  • Cooling System
    • Caterpillar extended life coolant
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Radiator stone guard
  • Generator
    • 12 Leads
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Starting/charging System
    • Batteries
    • 24V battery with rack and cables
Optional Equipment:
  • Certificates
    • IBC seismic and wind Certifications
  • Air Inlet System
    • Cartridge type air filter
  • Alternator System
    • R Frame auxilliary winding
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Circuit Breakers
    • Power terminal strip
    • Second circuit breaker box
    • Breakers (100% UL rated)
    • 3-Pole 100% rated
  • Control Panels
    • Volt free contacts genset run and common alarm
    • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
    • Discrete I/O module
    • Audible alarm
    • Ground fault relay
    • Remote annunciator module
    • NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
    • Oil temperature gauge and sender
    • Remote E-stop button
  • Enclosures
    • Panel viewing window
    • Sound attenuated enclosure, Level 2
    • External emergency stop
  • Heating Elements
    • Anti-condensation heater
    • Coolant heater
    • Lube oil sump heater
    • Wiring for canopy space heater
    • Jacket water heater
    • Battery heater
  • Cooling System
    • Radiator transition flange
  • Fuel System
    • Emergency vent pipe
    • Tank riser
    • 209 and 394 gallon sub-base fuel tanks
    • 5 Gallon fill containment
  • Mounting System
    • Seismic vibration isolators
  • Tests
    • PGS Test report @ 1.0 power factor
    • 4 Hour factory test
    • PGS Test report @ 0.8 power factor
    • Generator test report
  • Exhaust System
    • 10, 25 and 35 dBA silencer systems
    • Overhead silencer mounting kit
  • Generators
    • Permanent magnet excitation (PMG) generator
Compare Products