CN5086 Electric Motor |
C27 ACERT Tier 4i Oilfield Diesel Generator Set |
3512C (HD) Well Stimulation Engine with Dynamic Gas Blending Kit |
3512C (HD) Land Mechanical Drilling Engine |
|
Electric Motor Specifications |
||||
---|---|---|---|---|
Voltage/Frequency | 4000V ± 10%/60 Hz | - | - | - |
Type of EX-Protection | Class 1 Division 2, Group A,B,C,D T3 (NEC or CEC) | - | - | - |
Standards | NEMA MG1 | - | - | - |
Maximum Altitude - Before Derate | 3000 ft | - | - | - |
Service Factor | 1.15 SF | - | - | - |
No Load Current | 200 Amps | - | - | - |
Maximum Ambient Temperature | 104 °F | - | - | - |
Temperature Rise | Class B at rated load | - | - | - |
Shaft | 8.5 in | - | - | - |
Insulation | Class F | - | - | - |
Enclosure Type/Method of Cooling | WP-II | - | - | - |
Duty | Continuous | - | - | - |
Locked Rotor Amps | 520% Code E | - | - | - |
Full Load Current | 658 Amps | - | - | - |
Locked Rotor Torque | 60% | - | - | - |
Breakdown Torque | 190% | - | - | - |
Electric Motor Type | Squirrel Cage Induction Motor | - | - | - |
Mounting Designation | F1 or F2 | - | - | - |
Number of Poles | 8 | - | - | - |
Full Load Speed | 894 r/min | - | - | - |
Connection of Stator Winding | Star | - | - | - |
Rated Torque | 29366 lb/ft | - | - | - |
Engine Specifications |
||||
Maximum Rating | - | 725 ekW (907 - 1035 kVA) | - | 1475 BHP |
Minimum Rating | - | 725 ekW (907 - 1035 kVA) | - | 1250 BHP |
Emissions/Fuel Strategy | - | U.S. EPA Tier 2, U.S. EPA Tier 4 interim | - | - |
Aspiration | - | Turbocharged, aftercooled | - | Turbocharged-Aftercooled |
Manifold Type | - | Dry | - | - |
Bore | - | 5.4 in | - | 6.69 in |
Stroke | - | 6 in | - | 8.46 in |
Displacement | - | 1648 in³ | - | 3574 in³ |
Engine Control and Protection | - | ADEM A4 | - | - |
Generator Set Control | - | EMCP 4.2 | - | - |
Generator | - | SR4B | - | - |
Fuel System | - | MEUI | - | - |
Frequency - Speed | - | 60 Hz (1800 rpm) | - | - |
Emissions | - | - | - | U.S. EPA Non-road Tier 2 |
Rated Speed | - | - | - | 1200 r/min |
Governor and Protection | - | - | - | ADEM A3 |
Engine Weight - Net Dry | - | - | - | 11945 lb |
Rotation from Flywheel End | - | - | - | Counterclockwise |
Oil Change Interval | - | - | - | 500 |
Flywheel and Flywheel Housing | - | - | - | SAE No. 00 |
Flywheel Teeth | - | - | - | 183 |
Capacity for Liquids |
||||
Fuel | - | Diesel | - | - |
Minimum Cooling System - Engine Only | - | - | - | 41 gal (US) |
Dimensions |
||||
Length | - | 186 in | 110.4 in | 105.6 in |
Width | - | 77 in | 59.2 in | 70.5 in |
Height | - | 86 in | 86.3 in | 79.5 in |
Weight | - | 20000 lb | 14650 lb | - |
General Specifications |
||||
Maximum Rating | - | - | 2500 BHP | - |
Displacement | - | - | 3574 in³ | - |
Minimum Rating | - | - | 2150 BHP | - |
Aspiration | - | - | Turbocharged-Aftercooled | - |
Flywheel and Flywheel Housing | - | - | SAE No. 0 | - |
Flywheel Teeth | - | - | 151 | - |
Stroke | - | - | 8.5 in | - |
Bore | - | - | 6.7 in | - |
Emissions |
||||
Emissions | - | - | Non-current EPA Tier 2 | - |
Add a Similar Product:
- C18 ACERT™ Tier 4 Final Engine Add
- G3512 Add
- G3520 Add
- C32 ACERT Tier 2 Oilfield Diesel Generator Set Add
- C27 ACERT Tier 2 Oilfield Diesel Generator Set Add
- C15 ACERT Tier 4i Oilfield Diesel Generator Set Add
- C18 ACERT Tier 2 Oilfield Diesel Generator Set Add
- 3516 Land Mechanical Drilling Engine Add
- C15 ACERT Tier 2 Oilfield Diesel Generator Set Add
- G3520 Add