C32 ACERT Tier 2 Oilfield Diesel Generator Set
C15 ACERT Tier 2 Oilfield Diesel Generator Set

Engine Specifications

Maximum Rating 800 ekW (1000 kVA) 455 ekW (570 kVA) - -
Minimum Rating 910 ekW (1300 kVA) 292 ekW (365 kVA) - -
Emissions/Fuel Strategy U.S. EPA Tier 2 U.S. EPA Tier 2, U.S. EPA Tier 3, EU Stage II, China Phase II U.S. EPA Large S.I. Tier 2 / Non-Road Mobile Certified U.S. EPA Large S.I. Tier 2 / Non-Road Mobile Certified
Aspiration Turbocharged-Aftercooled Turbocharged, air-to-air aftercooled Turbocharged Turbocharged
Manifold Type Dry Dry - -
Bore 5.7 in 5.4 in 6.7 in 6.7 in
Stroke 6.4 in 6.75 in 8.5 in 8.5 in
Displacement 1959 in³ 927 in³ 5956 in³ 5956 in³
Engine Control and Protection ADEM A4 ADEM A4 Electronic (ADEM 4) Electronic (ADEM 4)
Generator Set Control EMCP 3.1 EMCP 3.1 EMCP 4 Control Panels EMCP 4 Control Panels
Generator SR4B SR4B - -
Fuel System MEUI MEUI Electronic Fuel Control Valve Electronic Fuel Control Valve
Frequency - Speed 50/60 Hz (1500/1800 rpm) 50/60 Hz (1500/1800 rpm) 60 Hz 60 Hz
Compression Ratio - - 11.5:1 11.5:1

Capacity for Liquids

Fuel Diesel Diesel - -

Dimensions

Length 206 in 138.5 in 336 in 336 in
Width 75 in 60 in 94 in 94 in
Height 86 in 83.1 in 128 in 128 in
Weight 20500 lb 10500 lb 48501 lb 48501 lb
Add a Similar Product:
  • 3512C (HD) Well Stimulation Engine with Dynamic Gas Blending Kit Add
  • C18 ACERT™ Tier 4 Final Engine Add
  • G3512 Add
  • C27 ACERT Tier 4i Oilfield Diesel Generator Set Add
  • C27 ACERT Tier 2 Oilfield Diesel Generator Set Add
  • C15 ACERT Tier 4i Oilfield Diesel Generator Set Add
  • C18 ACERT Tier 2 Oilfield Diesel Generator Set Add
  • 3516 Land Mechanical Drilling Engine Add
  • 3512C (HD) Land Mechanical Drilling Engine Add
  • 3512 Land Mechanical Drilling Engine Add