Compare Equipment Go Back

XQ125 Rental Power
Cat XLM Switchgear
Cat EGP Switchgear

Generator Set

Rating Prime 100 ekW (125 kVA) - -
Frequency 60 Hz - -
Voltage 120 - 600 V - -
Rating Standby 110 ekW (137 kVA) - -

Engine

Engine Cat C4.4 - -
Fuel Diesel - -

Dimensions

Height - Without Trailer 73 in - -
Length - Without Trailer 127 in - -
Width - Without Trailer 49 in - -
Weight with Lube Oil and Coolant, Without Trailer 5230 lb - -

Fuel Consumption

100% Load 60Hz 8.3 gal/hr - -
75% Load 60Hz 5.51 gal/hr - -
50% Load 60Hz 3.8 gal/hr - -

Noise rating (with enclosure)

Sound Power @ 7 meters (23 feet) @ Prime Rating 65 dB(A) - -
Sound Power @ 7 meters (23 feet) @ Standby Rating 66 dB(A) - -

Technical Summary

Configuration - Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
Modes of Operation - Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
Application - LV and MV ( 208V - 38 kV LV and MV (208V - 38 kV)

Generator Protective Devices

ANSI Protective Devices - 15/25, 27/59, 81 O/U, 32, 40, 50, 51 15/25, 27/59, 81 O/U, 32, 40, 50, 51

Utility Protective Devices

ANSI Protective Devices - 15/25, 27/59, 81 O/U, 32, 40, 47, 50, 51, 86 -

Environmental Parameters

Certifications - IBS, CBC, UBC & OSHPD Certified IBC, CBC, UBC & OSHPD Certified
Control Panel Enclosure - NEMA 1 or NEMA 3R, Freestanding Construction NEMA 1 or NEMA 3R Freestanding Construction
Operating Temperature - 0 degrees to 50 degrees C 0°C to 50°C
Storage Temperature - -20 degrees C to +60 degrees C -20°C to +60°C
Low Voltage Standards - NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70
Medium Voltage Standards - NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110
Add a Similar Product:
  • Cat Customizable Switchgear and Controls Add
  • Cat Switchgear Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • EMCP 4.4 Master Control Panel Add
  • Energy Time Shift (ETS) Module Add
  • Energy Capacity Expansion (ECE) module Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
  • Temporary Connection Boxes Add
  • XQ425 Add