Compare Equipment Go Back

Cat Customizable Switchgear and Controls
Engine Paralleling and Integration Control (EPIC)

Generator Set

Rating Prime 47.5 ekW (60 kVA) - -
Frequency 60 Hz - -
Voltage 120 - 600 V - -

Engine

Engine Cat C3.4 - -
Fuel Diesel - -

Dimensions

Height - Without Trailer 65.3 in - -
Length - Without Trailer 106.5 in - -
Width - Without Trailer 41.3 in - -
Weight with Lube Oil and Coolant, Without Trailer 1305 kg - -

Fuel Consumption

100% Load 60Hz 3.7 gal/hr - -
75% Load 60Hz 2.8 gal/hr - -
50% Load 60Hz 1.9 gal/hr - -

Noise rating (with enclosure)

Sound Power @ 7 meters (23 feet) @ All Ratings 63 dB(A) - -

Technical Summary

Configuration - Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)
Modes of Operation - All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
Application - LV and MV ( 208V - 38 kV) 50 / 60 Hz LV and MV (208V-27kV)

Generator Protective Devices

ANSI Protective Devices - Per customer specification 15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade)

Utility Protective Devices

ANSI Protective Devices - Per customer specification 15/25. 27/59, 81 O/U, 32,47 (Industrial Grade)

Environmental Parameters

Certifications - Per customer specification UL / cUL 508A
Control Panel Enclosure - Per customer specification NEMA 12
Operating Temperature - Per customer specification 0°C to 55°C
Storage Temperature - Per customer specification -20°C to 60°C
Low Voltage Standards - Per customer specification -
Medium Voltage Standards - Per customer specification -
Add a Similar Product:
  • Cat Switchgear Add
  • Cat EGP Switchgear Add
  • Cat XLM Switchgear Add
  • EMCP 4.4 Master Control Panel Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • Energy Time Shift (ETS) Module Add
  • Energy Capacity Expansion (ECE) module Add
  • Temporary Connection Boxes Add
  • XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
  • XQP550 EU Stage V Add