Temporary Connection Boxes
|
EMCP 4.4 Master Control Panel
|
|
Engine Paralleling and Integration Control (EPIC)
|
Cat® BDP1000 Bi-Directional Power Inverter
|
Generator Set Specifications |
Continuous Rating |
1000 ekW @1.0pf |
- |
- |
- |
- |
- |
Fuel Type |
Natural Gas, Hydrogen Blend (up to 25%) |
- |
- |
- |
- |
- |
Maximum Electrical Efficiency |
41.50% |
- |
- |
- |
- |
- |
Frequency |
50 Hz |
- |
- |
- |
- |
- |
RPM |
1500 rpm |
- |
- |
- |
- |
- |
Natural Gas Rating |
1000 |
- |
- |
- |
- |
- |
Engine Specifications |
Engine Model |
CG132B |
- |
- |
- |
- |
- |
Displacement |
2135.8 in³ |
- |
- |
- |
- |
- |
Aspiration |
TA |
- |
- |
- |
- |
- |
Bore |
5.2 in |
- |
- |
- |
- |
- |
Stroke |
6.3 in |
- |
- |
- |
- |
- |
Generator Set Dimensions |
Length |
165 in |
- |
- |
- |
- |
- |
Width |
70 in |
- |
- |
- |
- |
- |
Height |
85 in |
- |
- |
- |
- |
- |
Dry Weight - Genset |
17791 lb |
- |
- |
- |
- |
- |
Technical Summary |
Application |
- |
EMERGENCY, LEGALLY REQUIRED EMERGENCY AND STANDBY |
LV and MV (208V - 38 kV) |
LV and MV ( 208V - 38 kV |
LV and MV (208V-27kV) |
Energy Storage System |
Module Type |
- |
LUG-TO-LUG, CAMLOCK AND ENCLOSED CIRCUIT BREAKER |
- |
- |
- |
Integral part of Power Grid Stabilization and Energy Time Shift modules |
Rated Power |
- |
200 - 4000 AMPS |
- |
- |
- |
1000 kVA (1000kW 1PF) |
Configuration |
- |
- |
Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source. |
Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications |
Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control) |
- |
Modes of Operation |
- |
- |
Emergency standby, island, utility paralleling |
Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power |
Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel) |
- |
Generator Protective Devices |
ANSI Protective Devices |
- |
- |
15/25, 27/59, 81 O/U, 32, 40, 50, 51 |
15/25, 27/59, 81 O/U, 32, 40, 50, 51 |
15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade) |
- |
Utility Protective Devices |
ANSI Protective Devices |
- |
- |
15/25. 27/59, 81 O/U, 32,47 (Industrial Grade) |
15/25, 27/59, 81 O/U, 32, 40, 47, 50, 51, 86 |
15/25. 27/59, 81 O/U, 32,47 (Industrial Grade) |
- |
Environmental Parameters |
Certifications |
- |
- |
IBC, CBC, UBC & OSHPD Certified |
IBS, CBC, UBC & OSHPD Certified |
UL / cUL 508A |
- |
Control Panel Enclosure |
- |
- |
NEMA 1 wall-mounted construction |
NEMA 1 or NEMA 3R, Freestanding Construction |
NEMA 12 |
- |
Operating Temperature |
- |
- |
0°C to 50°C |
0 degrees to 50 degrees C |
0°C to 55°C |
- |
Storage Temperature |
- |
- |
-20°C to +60°C |
-20 degrees C to +60 degrees C |
-20°C to 60°C |
- |
Low Voltage Standards |
- |
- |
NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 |
NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 |
- |
- |
Medium Voltage Standards |
- |
- |
NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 |
NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 |
- |
- |