Compare Equipment Go Back

CG132B-8 Gas Generator Set
Cat Customizable Switchgear and Controls
Energy Capacity Expansion (ECE) module
Cat XLM Switchgear

Generator Set Specifications

Continuous Rating 400 ekW @1.0pf - - -
Fuel Type Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%) - - -
Maximum Electrical Efficiency 43.1% / 42.1% - - -
Frequency 50 / 60 Hz - - -
RPM 1500 or 1800 rpm - - -

Engine Specifications

Engine Model CG132-8 - - -
Displacement 1067.9 in³ - - -
Aspiration TA - - -
Bore 5.2 in - - -
Stroke 6.3 in - - -

Generator Set Dimensions

Length 122 in - - -
Width 70 in - - -
Height 85 in - - -
Dry Weight - Genset 12610 lb - - -

Technical Summary

Configuration - Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc - Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications
Modes of Operation - All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow - Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
Application - LV and MV ( 208V - 38 kV) 50 / 60 Hz Reserve Power Capacity LV and MV ( 208V - 38 kV
Module Type - - Energy Storage -
Nameplate Energy Capacity - - 1518 kWh - 7590 kWh -

Generator Protective Devices

ANSI Protective Devices - Per customer specification - 15/25, 27/59, 81 O/U, 32, 40, 50, 51

Utility Protective Devices

ANSI Protective Devices - Per customer specification - 15/25, 27/59, 81 O/U, 32, 40, 47, 50, 51, 86

Environmental Parameters

Certifications - Per customer specification - IBS, CBC, UBC & OSHPD Certified
Control Panel Enclosure - Per customer specification - NEMA 1 or NEMA 3R, Freestanding Construction
Operating Temperature - Per customer specification - 0 degrees to 50 degrees C
Storage Temperature - Per customer specification - -20 degrees C to +60 degrees C
Low Voltage Standards - Per customer specification - NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70
Medium Voltage Standards - Per customer specification - NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110
Add a Similar Product:
  • Cat Switchgear Add
  • Cat EGP Switchgear Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • EMCP 4.4 Master Control Panel Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • Energy Time Shift (ETS) Module Add
  • XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
  • Temporary Connection Boxes Add
  • XQP550 EU Stage V Add
  • XQ230 Rental Power Add