|
|
XQ570 Tier 4 Final - 455 ekW (568 kVA)
|
Cat Customizable Switchgear and Controls
|
|
Cat® BDP1000 Bi-Directional Power Inverter
|
Generator Set Specifications |
Continuous Rating |
1085 ekW |
- |
- |
- |
- |
Fuel Type |
Natural Gas, Biogas, Coal Gas |
- |
- |
- |
- |
Maximum Electrical Efficiency |
36.50% |
- |
- |
- |
- |
Maximum Standby Rating |
1000 kw |
- |
- |
- |
- |
Frequency |
50 / 60 Hz |
- |
- |
- |
- |
RPM |
1200 / 1500 rpm |
- |
- |
- |
- |
Engine Specifications |
Engine Model |
G3516A |
- |
- |
- |
- |
Displacement |
4210 in³ |
- |
- |
- |
- |
Aspiration |
TA |
- |
- |
- |
- |
Bore |
6.7 in |
- |
- |
- |
- |
Stroke |
7.5 in |
- |
- |
- |
- |
Generator Set Dimensions |
Length |
193 in |
- |
- |
- |
- |
Width |
68 in |
- |
- |
- |
- |
Height |
76 in |
- |
- |
- |
- |
Dry Weight - Genset |
27670 lb |
- |
- |
- |
- |
Generator Set |
Rating Prime |
- |
455 ekW (568 kVA) |
- |
550 kVA |
- |
Frequency |
- |
60 Hz |
- |
50/60 Hz |
- |
Voltage |
- |
120 - 600 V |
- |
220 - 480 V |
- |
Rating Standby |
- |
500 ekW (625 kVA) |
- |
- |
- |
Fuel/Emissions Strategy |
- |
- |
- |
EU Stage V |
- |
Engine |
Engine |
- |
Cat C18 |
- |
Cat® C18 |
- |
Fuel |
- |
Diesel |
- |
Diesel |
- |
Dimensions |
Height - Without Trailer |
- |
102 in |
- |
- |
- |
Length - Without Trailer |
- |
240 in |
- |
- |
- |
Width - Without Trailer |
- |
96 in |
- |
- |
- |
Weight with Lube Oil and Coolant, Without Trailer |
- |
24125 lb |
- |
- |
- |
Width |
- |
- |
- |
80.3 in |
- |
Height |
- |
- |
- |
90.5 in |
- |
Length |
- |
- |
- |
213.3 in |
- |
Weight - With Lube Oil and Coolant |
- |
- |
- |
14860 lb |
- |
Fuel Consumption |
100% Load 60Hz |
- |
35.9 gal/hr |
- |
- |
- |
75% Load 60Hz |
- |
28.3 gal/hr |
- |
- |
- |
50% Load 60Hz |
- |
20.5 gal/hr |
- |
- |
- |
100% Load 60 Hz |
- |
- |
- |
34.3 gal/hr |
- |
100% Load 50 Hz |
- |
- |
- |
33.4 gal/hr |
- |
75% Load 60 Hz |
- |
- |
- |
26.13 gal/hr |
- |
75% Load 50 Hz |
- |
- |
- |
24.9 gal/hr |
- |
Noise rating (with enclosure) |
Sound Power @ 7 meters (23 feet) @ All Ratings |
- |
74 dB(A) |
- |
- |
- |
Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz) |
- |
- |
- |
79.19 |
- |
Technical Summary |
Configuration |
- |
- |
Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc |
- |
- |
Modes of Operation |
- |
- |
All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow |
- |
- |
Application |
- |
- |
LV and MV ( 208V - 38 kV) 50 / 60 Hz |
- |
Energy Storage System |
Module Type |
- |
- |
- |
- |
Integral part of Power Grid Stabilization and Energy Time Shift modules |
Rated Power |
- |
- |
- |
- |
1000 kVA (1000kW 1PF) |
Generator Protective Devices |
ANSI Protective Devices |
- |
- |
Per customer specification |
- |
- |
Utility Protective Devices |
ANSI Protective Devices |
- |
- |
Per customer specification |
- |
- |
Environmental Parameters |
Certifications |
- |
- |
Per customer specification |
- |
- |
Control Panel Enclosure |
- |
- |
Per customer specification |
- |
- |
Operating Temperature |
- |
- |
Per customer specification |
- |
- |
Storage Temperature |
- |
- |
Per customer specification |
- |
- |
Low Voltage Standards |
- |
- |
Per customer specification |
- |
- |
Medium Voltage Standards |
- |
- |
Per customer specification |
- |
- |