Compare Equipment Go Back
Gas Generator G3512H |
Cat Customizable Switchgear and Controls |
|
|
Generator Set Specifications |
|||
---|---|---|---|
Continuous Rating | 1515 ekW / 1505 ekW @1.0pf | - | - |
Fuel Type | Natural Gas, Hydrogen Blend (up to 25%) | - | - |
Maximum Electrical Efficiency | 44.90% | - | - |
Frequency | 50 / 60 Hz | - | - |
RPM | 1500 rpm | - | - |
Engine Specifications |
|||
Engine Model | G3512H | - | - |
Displacement | 3574 in³ | - | - |
Aspiration | TA | - | - |
Bore | 6.7 in | - | - |
Stroke | 8.5 in | - | - |
Governor Type | ADEM A4 | - | - |
Generator Set Dimensions |
|||
Length | 223 in | - | - |
Width | 76 in | - | - |
Height | 91 in | - | - |
Dry Weight - Genset | 31085 lb | - | - |
Technical Summary |
|||
Configuration | - | Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc | - |
Modes of Operation | - | All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow | - |
Application | - | LV and MV ( 208V - 38 kV) 50 / 60 Hz | - |
Generator Protective Devices |
|||
ANSI Protective Devices | - | Per customer specification | - |
Utility Protective Devices |
|||
ANSI Protective Devices | - | Per customer specification | - |
Environmental Parameters |
|||
Certifications | - | Per customer specification | - |
Control Panel Enclosure | - | Per customer specification | - |
Operating Temperature | - | Per customer specification | - |
Storage Temperature | - | Per customer specification | - |
Low Voltage Standards | - | Per customer specification | - |
Medium Voltage Standards | - | Per customer specification | - |
Add a Similar Product:
- Cat Switchgear Add
- Cat EGP Switchgear Add
- Cat XLM Switchgear Add
- Cat® BDP1000 Bi-Directional Power Inverter Add
- Engine Paralleling and Integration Control (EPIC) Add
- EMCP 4.4 Master Control Panel Add
- Energy Time Shift (ETS) Module Add
- Energy Capacity Expansion (ECE) module Add
- XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
- Temporary Connection Boxes Add