Compare Equipment Go Back

G3512 1000kW Gas Generator Set
XQ570 Tier 4 Final - 455 ekW (568 kVA)
Cat Customizable Switchgear and Controls

Generator Set Specifications

Gas Standby Rating 1000 ekW @ 0.8pf - -
Fuel Type Natural Gas, Hydrogen Blend (up to 5%) - -
Emissions/Fuel Strategy U.S. EPA Certified for Non-Emergency Stationary Genset - -
RPM 1800 rpm - -
Frequency 60 Hz - -
Compression Ratio 9.7 - -
Displacement 3173 in³ - -

Engine Specifications

Engine Model G3512 - -
Displacement 3173 in³ - -
Aspiration TA - -
Bore 6.7 in - -
Stroke 7.5 in - -

Generator Set Dimensions

Length 205.7 in - -
Width 90 in - -
Height 99.4 in - -
Weight 27500 lb - -

Generator Set

Rating Prime - 455 ekW (568 kVA) -
Frequency - 60 Hz -
Voltage - 120 - 600 V -
Rating Standby - 500 ekW (625 kVA) -

Engine

Engine - Cat C18 -
Fuel - Diesel -

Dimensions

Height - Without Trailer - 102 in -
Length - Without Trailer - 240 in -
Width - Without Trailer - 96 in -
Weight with Lube Oil and Coolant, Without Trailer - 24125 lb -

Fuel Consumption

100% Load 60Hz - 35.9 gal/hr -
75% Load 60Hz - 28.3 gal/hr -
50% Load 60Hz - 20.5 gal/hr -

Noise rating (with enclosure)

Sound Power @ 7 meters (23 feet) @ All Ratings - 74 dB(A) -

Technical Summary

Configuration - - Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
Modes of Operation - - All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow
Application - - LV and MV ( 208V - 38 kV) 50 / 60 Hz

Generator Protective Devices

ANSI Protective Devices - - Per customer specification

Utility Protective Devices

ANSI Protective Devices - - Per customer specification

Environmental Parameters

Certifications - - Per customer specification
Control Panel Enclosure - - Per customer specification
Operating Temperature - - Per customer specification
Storage Temperature - - Per customer specification
Low Voltage Standards - - Per customer specification
Medium Voltage Standards - - Per customer specification
Add a Similar Product:
  • Cat Switchgear Add
  • Cat XLM Switchgear Add
  • Cat EGP Switchgear Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • EMCP 4.4 Master Control Panel Add
  • Energy Capacity Expansion (ECE) module Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • Energy Time Shift (ETS) Module Add
  • Temporary Connection Boxes Add
  • XQP550 EU Stage V Add