Compare Equipment Go Back
DG350-2 (Single-phase) |
Cat Customizable Switchgear and Controls |
Energy Time Shift (ETS) Module |
|
Generator Set Specifications |
|||
---|---|---|---|
Frequency | 60 Hz | - | - |
Natural Gas Rating | 350 eKW | - | - |
Emissions/Fuel Strategy | U.S. EPA Certified for Non-Emergency Application | - | - |
Fuel Type | Natural Gas | - | - |
Displacement | 1336.42 in³ | - | - |
Speed | 1800 rpm | - | - |
Engine Specifications |
|||
Engine Model | G21.9L Spark-Ignited | - | - |
Compression Ratio | 10.1 | - | - |
Fuel System | Carburetor, Down Draft | - | - |
Governor Type | Electronic | - | - |
Aspiration | Turbocharged - Aftercooled | - | - |
Bore | 5.03 in | - | - |
Stroke | 5.6 in | - | - |
Generator Set Dimensions |
|||
Length | 154.4 in | - | - |
Width | 71 in | - | - |
Height | 67.6 in | - | - |
Weight | 8274 lb | - | - |
Technical Summary |
|||
Configuration | - | Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc | - |
Modes of Operation | - | All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow | - |
Application | - | LV and MV ( 208V - 38 kV) 50 / 60 Hz | Peak Shaving |
Module Type | - | - | Energy Time Shift |
Nameplate Power | - | - | 570 kW | 1000 kW |
Nameplate Energy Capacity | - | - | 1518 kWh |
Generator Protective Devices |
|||
ANSI Protective Devices | - | Per customer specification | - |
Utility Protective Devices |
|||
ANSI Protective Devices | - | Per customer specification | - |
Environmental Parameters |
|||
Certifications | - | Per customer specification | - |
Control Panel Enclosure | - | Per customer specification | - |
Operating Temperature | - | Per customer specification | - |
Storage Temperature | - | Per customer specification | - |
Low Voltage Standards | - | Per customer specification | - |
Medium Voltage Standards | - | Per customer specification | - |
Add a Similar Product:
- Cat XLM Switchgear Add
- Cat Switchgear Add
- EMCP 4.4 Master Control Panel Add
- Cat EGP Switchgear Add
- Engine Paralleling and Integration Control (EPIC) Add
- Cat® BDP1000 Bi-Directional Power Inverter Add
- Energy Capacity Expansion (ECE) module Add
- Temporary Connection Boxes Add
- XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
- XQP550 EU Stage V Add