Compare Equipment Go Back

DG275-2 (3 phase)
Cat Customizable Switchgear and Controls
DE110 GC Generator Set (50 Hz)
Energy Time Shift (ETS) Module

Generator Set Specifications

Frequency 60 Hz - 50 Hz -
Natural Gas Rating 275 eKW - - -
Emissions/Fuel Strategy U.S. EPA Certified for Non-Emergency Application - Non Regulated -
Displacement 864.71 in³ - - -
Speed 1800 rpm - 1500 rpm -
Maximum Rating - - 110 kVA -
Minimum Rating - - 110 kVA -
Voltage - - 380 to 415 Volts -
Duty Cycle - - Standby -

Engine Specifications

Fuel System Carburetor, Down Draft - Inline -
Compression Ratio 9.5:1 - 18.23:1 -
Bore 5.31 in - 4.1 in -
Stroke 6.5 in - 5 in -
Engine Model - - C4.4, In-line 4, 4-cycle diesel -
Displacement - - 268.5 in -
Aspiration - - Turbocharged Air To Air Charge Cooled -
Governor Type - - Mechanical -

Generator Set Dimensions

Length 136 in - - -
Width 57.6 in - - -
Height 66.1 in - - -
Weight 6274 lb - - -
Length - Maximum - - 108.1 in -
Width - Maximum - - 39.3 in -
Height - Maximum - - 58.1 in -
Dry Weight - Genset (maximum) - - 1330 lb -

Technical Summary

Configuration - Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc - -
Modes of Operation - All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow - -
Application - LV and MV ( 208V - 38 kV) 50 / 60 Hz - Peak Shaving
Module Type - - - Energy Time Shift
Nameplate Power - - - 570 kW | 1000 kW
Nameplate Energy Capacity - - - 1518 kWh

Generator Protective Devices

ANSI Protective Devices - Per customer specification - -

Utility Protective Devices

ANSI Protective Devices - Per customer specification - -

Environmental Parameters

Certifications - Per customer specification - -
Control Panel Enclosure - Per customer specification - -
Operating Temperature - Per customer specification - -
Storage Temperature - Per customer specification - -
Low Voltage Standards - Per customer specification - -
Medium Voltage Standards - Per customer specification - -
Add a Similar Product:
  • Cat Switchgear Add
  • Cat XLM Switchgear Add
  • Cat EGP Switchgear Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • EMCP 4.4 Master Control Panel Add
  • Energy Capacity Expansion (ECE) module Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
  • Temporary Connection Boxes Add
  • XQP550 EU Stage V Add