Compare Equipment Go Back
DG275-2 (3 phase) |
EMCP 4.4 Master Control Panel |
Cat Customizable Switchgear and Controls |
|
Generator Set Specifications |
|||
---|---|---|---|
Frequency | 60 Hz | - | - |
Natural Gas Rating | 275 eKW | - | - |
Emissions/Fuel Strategy | U.S. EPA Certified for Non-Emergency Application | - | - |
Displacement | 864.71 in³ | - | - |
Speed | 1800 rpm | - | - |
Engine Specifications |
|||
Fuel System | Carburetor, Down Draft | - | - |
Compression Ratio | 9.5:1 | - | - |
Bore | 5.31 in | - | - |
Stroke | 6.5 in | - | - |
Generator Set Dimensions |
|||
Length | 136 in | - | - |
Width | 57.6 in | - | - |
Height | 66.1 in | - | - |
Weight | 6274 lb | - | - |
Technical Summary |
|||
Configuration | - | Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source. | Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc |
Modes of Operation | - | Emergency standby, island, utility paralleling | All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow |
Application | - | LV and MV (208V - 38 kV) | LV and MV ( 208V - 38 kV) 50 / 60 Hz |
Generator Protective Devices |
|||
ANSI Protective Devices | - | 15/25, 27/59, 81 O/U, 32, 40, 50, 51 | Per customer specification |
Utility Protective Devices |
|||
ANSI Protective Devices | - | 15/25. 27/59, 81 O/U, 32,47 (Industrial Grade) | Per customer specification |
Environmental Parameters |
|||
Certifications | - | IBC, CBC, UBC & OSHPD Certified | Per customer specification |
Control Panel Enclosure | - | NEMA 1 wall-mounted construction | Per customer specification |
Operating Temperature | - | 0°C to 50°C | Per customer specification |
Storage Temperature | - | -20°C to +60°C | Per customer specification |
Low Voltage Standards | - | NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 | Per customer specification |
Medium Voltage Standards | - | NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 | Per customer specification |
Add a Similar Product:
- Cat Switchgear Add
- Cat XLM Switchgear Add
- Cat EGP Switchgear Add
- Engine Paralleling and Integration Control (EPIC) Add
- Cat® BDP1000 Bi-Directional Power Inverter Add
- Energy Capacity Expansion (ECE) module Add
- Energy Time Shift (ETS) Module Add
- XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
- Temporary Connection Boxes Add
- XQP550 EU Stage V Add