Compare Equipment Go Back

DG275-2 (3 phase)
XQ570 Tier 4 Final - 455 ekW (568 kVA)
Cat Customizable Switchgear and Controls

Generator Set Specifications

Frequency 60 Hz - -
Natural Gas Rating 275 eKW - -
Emissions/Fuel Strategy U.S. EPA Certified for Non-Emergency Application - -
Displacement 864.71 in³ - -
Speed 1800 rpm - -

Engine Specifications

Fuel System Carburetor, Down Draft - -
Compression Ratio 9.5:1 - -
Bore 5.31 in - -
Stroke 6.5 in - -

Generator Set Dimensions

Length 136 in - -
Width 57.6 in - -
Height 66.1 in - -
Weight 6274 lb - -

Generator Set

Rating Prime - 455 ekW (568 kVA) -
Frequency - 60 Hz -
Voltage - 120 - 600 V -
Rating Standby - 500 ekW (625 kVA) -

Engine

Engine - Cat C18 -
Fuel - Diesel -

Dimensions

Height - Without Trailer - 102 in -
Length - Without Trailer - 240 in -
Width - Without Trailer - 96 in -
Weight with Lube Oil and Coolant, Without Trailer - 24125 lb -

Fuel Consumption

100% Load 60Hz - 35.9 gal/hr -
75% Load 60Hz - 28.3 gal/hr -
50% Load 60Hz - 20.5 gal/hr -

Noise rating (with enclosure)

Sound Power @ 7 meters (23 feet) @ All Ratings - 74 dB(A) -

Technical Summary

Configuration - - Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
Modes of Operation - - All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow
Application - - LV and MV ( 208V - 38 kV) 50 / 60 Hz

Generator Protective Devices

ANSI Protective Devices - - Per customer specification

Utility Protective Devices

ANSI Protective Devices - - Per customer specification

Environmental Parameters

Certifications - - Per customer specification
Control Panel Enclosure - - Per customer specification
Operating Temperature - - Per customer specification
Storage Temperature - - Per customer specification
Low Voltage Standards - - Per customer specification
Medium Voltage Standards - - Per customer specification
Add a Similar Product:
  • Cat Switchgear Add
  • Cat EGP Switchgear Add
  • Cat XLM Switchgear Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • EMCP 4.4 Master Control Panel Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • Energy Time Shift (ETS) Module Add
  • Energy Capacity Expansion (ECE) module Add
  • Temporary Connection Boxes Add
  • XQ425 Add