Compare Equipment Go Back
DG175-2 (Single-phase) |
Cat Customizable Switchgear and Controls |
Energy Capacity Expansion (ECE) module |
XQP550 EU Stage V |
|
Generator Set Specifications |
||||
---|---|---|---|---|
Frequency | 60 Hz | - | - | - |
Natural Gas Rating | 175 ekW | - | - | - |
Emissions/Fuel Strategy | U.S. EPA Certified for Non-Emergency Application | - | - | - |
Displacement | 864.71 in | - | - | - |
Fuel Type | Natural Gas | - | - | - |
Speed | 1800 rpm | - | - | - |
Engine Specifications |
||||
Engine Model | G14.2L Inline 6, 4 cycle, Spark Ignited | - | - | - |
Fuel System | Carburetor, Down Draft | - | - | - |
Aspiration | Turbocharged - Aftercooled | - | - | - |
Governor Type | Electronic | - | - | - |
Compression Ratio | 9.5:1 | - | - | - |
Bore | 5.31 in | - | - | - |
Stroke | 6.5 in | - | - | - |
Generator Set Dimensions |
||||
Length | 127.95 in | - | - | - |
Width | 52.93 in | - | - | - |
Height | 67.37 in | - | - | - |
Weight | 5756 lb | - | - | - |
Technical Summary |
||||
Configuration | - | Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc | - | - |
Modes of Operation | - | All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow | - | - |
Application | - | LV and MV ( 208V - 38 kV) 50 / 60 Hz | Reserve Power Capacity | - |
Module Type | - | - | Energy Storage | - |
Nameplate Energy Capacity | - | - | 1518 kWh - 7590 kWh | - |
Generator Protective Devices |
||||
ANSI Protective Devices | - | Per customer specification | - | - |
Utility Protective Devices |
||||
ANSI Protective Devices | - | Per customer specification | - | - |
Environmental Parameters |
||||
Certifications | - | Per customer specification | - | - |
Control Panel Enclosure | - | Per customer specification | - | - |
Operating Temperature | - | Per customer specification | - | - |
Storage Temperature | - | Per customer specification | - | - |
Low Voltage Standards | - | Per customer specification | - | - |
Medium Voltage Standards | - | Per customer specification | - | - |
Generator Set |
||||
Rating Prime | - | - | - | 550 kVA |
Frequency | - | - | - | 50/60 Hz |
Voltage | - | - | - | 220 - 480 V |
Fuel/Emissions Strategy | - | - | - | EU Stage V |
Engine |
||||
Engine | - | - | - | Cat® C18 |
Fuel | - | - | - | Diesel |
Dimensions |
||||
Width | - | - | - | 80.3 in |
Height | - | - | - | 90.5 in |
Length | - | - | - | 213.3 in |
Weight - With Lube Oil and Coolant | - | - | - | 14860 lb |
Fuel Consumption |
||||
100% Load 60 Hz | - | - | - | 129.7 gal/hr |
100% Load 50 Hz | - | - | - | 18.7 gal/hr |
75% Load 60 Hz | - | - | - | 0 gal/hr |
75% Load 50 Hz | - | - | - | 23.1 gal/hr |
Noise rating (with enclosure) |
||||
Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz) | - | - | - | 79.19 |
Add a Similar Product:
- Cat Switchgear Add
- Cat EGP Switchgear Add
- Cat XLM Switchgear Add
- Engine Paralleling and Integration Control (EPIC) Add
- EMCP 4.4 Master Control Panel Add
- Cat® BDP1000 Bi-Directional Power Inverter Add
- XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
- Temporary Connection Boxes Add
- Energy Time Shift (ETS) Module Add
- XQ425 Add