Compare Equipment Go Back

3512 Generator Set
C280-12 Generator Set (Medium Speed)
3612 Generator Set (Medium Speed)

Generator Set Specifications

Standby Rating 1250/1100 ekW - -
Prime Power Rating 1135/1000 ekW - -
Emissions/Fuel Strategy Low Fuel Consumption - Low Fuel Consumption
Voltage 380 to 13800 Volts - -
Frequency 60 Hz - 50 Hz
Speed 1800 rpm - 750 & 1000 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous - Prime, Continuous
Maximum Rating 1250 ekW - 4850 kVA
Minimum Rating 890 ekW - 4400 kVA

Engine Specifications

Engine Model 3512 TA, V-12, 4-Stroke Water-Cooled Diesel - 3612 V-12,4-Stroke Water-Cooled Diesel
Bore 6.69 in - 11 in
Stroke 7.48 in - 11.8 in
Displacement 3161.03 in³ - 13524 in³
Compression Ratio 13.5:1 - 13:01
Aspiration TA - TA
Fuel System Direct Unit Injection - Direct unit injection
Governor Type Woodward - Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Minimum 214.8 in - -
Length - Maximum 218.8 in - 404 in
Width - Maximum 77.8 in - 99.62 in
Height - Maximum 93.2 in - 156.6 in
Dry Weight - Genset (minimum) 22210 lb - -
Dry Weight - Genset (maximum) 22650 lb - 112690 lb
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • 3616 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-16 Tier 4 Final Add
  • C175-20 Add