Compare Equipment Go Back

C27 Generator Set
C280-8 Generator Set (Medium Speed)
3616 Generator Set (Medium Speed)

Generator Set Specifications

Maximum Rating 800 ekW 2420 ekW (60Hz), 3250 kVA (50Hz) 7520 kVA
Minimum Rating 635 ekW 2200 ekW (60Hz), 2938 kVA (50Hz) 4700 kVA
Emissions/Fuel Strategy Low Fuel, Tier 2 Nonroad Equivalent EPA Tier 4 Final, IMO Tier 2 Low Fuel Consumption
Voltage 208 to 600 Volts - -
Frequency 60 Hz 50 / 60 Hz 50 Hz
Speed 1800 rpm 900 / 1000 rpm 720 & 1000 rpm
Duty Cycle Standby, Prime Prime, Continuous Standby, Prime, Continuous

Engine Specifications

Engine Model C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel
Bore 5.4 in 11 in 11 in
Stroke 6 in 11.8 in 11.8 in
Displacement 1649.47 in³ 9064 in³ 18032 in³
Compression Ratio 16.1:1 13:01 13:01
Aspiration TA TA TA
Fuel System MEUI Direct unit injection Direct unit injection
Governor Type Adem™A4 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Maximum 184 in 404 in 404 in
Width - Maximum 67.8 in 99.62 in 99.62 in
Height - Maximum 85.1 in 156.6 in 156.6 in
Dry Weight - Genset (maximum) - 91050 lb 141840 lb
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • C280-12 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-16 Tier 4 Final Add
  • C175-20 Add