C27 Generator Set
3606 Generator Set (Medium Speed)
C280-8 Generator Set (Medium Speed)

Generator Set Specifications

Maximum Rating 800 ekW 2688 kVA 2420 ekW (60Hz), 3250 kVA (50Hz)
Minimum Rating 635 ekW 1775 kVA 2200 ekW (60Hz), 2938 kVA (50Hz)
Emissions/Fuel Strategy Low Fuel, Tier 2 Nonroad Equivalent Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2
Voltage 208 to 600 Volts - -
Frequency 60 Hz 50 Hz 50 / 60 Hz
Speed 1800 rpm 750 & 1000 rpm 900 / 1000 rpm
Duty Cycle Standby, Prime Continuous Prime, Continuous

Engine Specifications

Engine Model C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel 3606 I-6, 4-Stroke Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel
Bore 5.4 in 11 in 11 in
Stroke 6 in 11.8 in 11.8 in
Displacement 1649.47 in³ 6762 in³ 9064 in³
Compression Ratio 16.1:1 13:01 13:01
Aspiration TA TA TA
Fuel System MEUI Direct unit injection Direct unit injection
Governor Type Adem™A4 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Maximum 184 in 404 in 404 in
Width - Maximum 67.8 in 99.62 in 99.62 in
Height - Maximum 85.1 in 156.6 in 156.6 in
Dry Weight - Genset (maximum) - 74970 lb 91050 lb