Compare Equipment Go Back

D300 GC (60 Hz) Generator Set
3616 Generator Set (Medium Speed)

Generator Set Specifications

Maximum Rating 300 ekW 4000 ekW 7520 kVA
Minimum Rating 300 ekW 3150 ekW 4700 kVA
Emissions/Fuel Strategy EPA Stationary Emergency Low Fuel, Tier 2 Low Fuel Consumption
Voltage 208 to 600 Volts 480 to 13800 Volts -
Frequency 60 Hz 60 Hz 50 Hz
Speed 1800 rpm 1800 rpm 720 & 1000 rpm
Duty Cycle Standby Standby, Mission Critical, Prime, Continuous Standby, Prime, Continuous
Standby Rating - 4000 (no fan)/3900/3620(no fan)/3500 ekW -
Prime Power Rating - 3600 (no fan)/3500/3300 (no fan)/3180 ekW -

Engine Specifications

Engine Model Cat® C9 In-line 6, 4-cycle diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel
Bore 4.4 in 6.89 in 11 in
Stroke 5.9 in 8.66 in 11.8 in
Displacement 538 in³ 6456.31 in³ 18032 in³
Compression Ratio 16.3:1 15.3:1 13:01
Aspiration Turbocharged Air-to-Air Aftercooled Turbo Aftercooled TA
Fuel System HEUI Common Rail Direct unit injection
Governor Type Adem™A4 ADEM� A4 Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Maximum 155.5 in 330.6 in 404 in
Width - Minimum 56.3 in 85.4 in -
Width - Maximum 56.7 in 127.7 in 99.62 in
Height - Minimum 67.2 in 87.6 in -
Height - Maximum 86.7 in 150.7 in 156.6 in
Dry Weight - Genset (minimum) 5518.2 lb 55100 lb -
Dry Weight - Genset (maximum) 6929.1 lb 66200 lb 141840 lb
Length - Minimum - 261.5 in -
Add a Similar Product:
  • C280-12 Generator Set (Medium Speed) Add
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-16 Generator Set Add