C9 Generator Set
3608 Generator Set (Medium Speed)
3612 Generator Set (Medium Speed)

Generator Set Specifications

Maximum Rating 330 kVA 2660 ekW 4850 kVA
Minimum Rating 230 kVA 1830 ekW 4400 kVA
Emissions/Fuel Strategy EU Stage IIIA Low Fuel Consumption Low Fuel Consumption
Voltage 200 to 400 Volts - -
Frequency 50 Hz 60 Hz 50 Hz
Speed 1500 rpm 720 & 900 rpm 750 & 1000 rpm
Duty Cycle Standby, Prime Standby, Prime, Continuous Prime, Continuous

Engine Specifications

Engine Model C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel 3612 V-12,4-Stroke Water-Cooled Diesel
Bore 4.41 in 11 in 11 in
Stroke 5.87 in 11.8 in 11.8 in
Displacement 537.01 in³ 9064 in³ 13524 in³
Compression Ratio 16.1:1 13:01 13:01
Aspiration Air to Air Aftercooled TA TA
Fuel System Hydraulic electronic unit injection Direct unit injection Direct unit injection
Governor Type Adem™A4 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Maximum 157 in 404 in 404 in
Width - Maximum 47.5 in 99.62 in 99.62 in
Height - Maximum 73.5 in 156.6 in 156.6 in
Dry Weight - Genset (maximum) - 91050 lb 112690 lb