Compare Equipment Go Back

DE110 GC Generator Set (60 Hz)
3608 Generator Set (Medium Speed)
3616 Generator Set (Medium Speed)
C280-12 Generator Set (Medium Speed)

Generator Set Specifications

Maximum Rating 100 ekW 2660 ekW 7520 kVA 3640 ekW (60Hz), 4850 kVA (50Hz)
Minimum Rating 100 ekW 1830 ekW 4700 kVA 3300 ekW (60Hz), 4400 kVA (50Hz)
Emissions/Fuel Strategy Non Regulated Low Fuel Consumption Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2
Voltage 220 to 480 Volts - - -
Frequency 60 Hz 60 Hz 50 Hz 50 / 60 Hz
Speed 1800 rpm 720 & 900 rpm 720 & 1000 rpm 900 / 1000 rpm
Duty Cycle Standby Standby, Prime, Continuous Standby, Prime, Continuous Prime, Continuous

Engine Specifications

Engine Model C4.4, In-line 4, 4-cycle diesel 3608 I-8,4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel
Bore 4.1 in 11 in 11 in 11 in
Stroke 5 in 11.8 in 11.8 in 11.8 in
Displacement 268.5 in 9064 in³ 18032 in³ 13524 in³
Compression Ratio 18.23:1 13:01 13:01 13:01
Aspiration Turbocharged Air To Air Charge Cooled TA TA TA
Fuel System Inline Direct unit injection Direct unit injection Direct unit injection
Governor Type Mechanical Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Maximum 108.1 in 404 in 404 in 404 in
Width - Maximum 39.3 in 99.62 in 99.62 in 99.62 in
Height - Maximum 58.1 in 156.6 in 156.6 in 156.6 in
Dry Weight - Genset (maximum) 2932 lb 91050 lb 141840 lb 112690 lb
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-16 Tier 4 Final Add
  • C175-20 Add
  • 3516E Low Voltage Generator Set Add