Generator Set Specifications

Maximum Rating 50 ekW 3100 ekW -
Minimum Rating 50 ekW 2500 ekW -
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3, SCAQMD Compliant U.S. EPA Certified Tier 4 -
Voltage 208 to 600 Volts 480 to 13800 Volts -
Frequency 60 Hz 60 Hz -
Speed 1800 rpm 1800 rpm -
Duty Cycle Standby Standby, Mission Critical, Prime, Continuous -
Standby Rating - 3100(no fan)/3000 ekW -
Prime Power Rating - 2825(no fan)/2725 ekW -

Engine Specifications

Engine Model C4.4, In-line 4, 4-cycle diesel C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel -
Bore 4.1 in 6.89 in -
Stroke 5 in 8.66 in -
Displacement 269 in 5155.88 in³ -
Compression Ratio 18.2:1 16.7:1 -
Aspiration Turbocharged Turbo Aftercooled -
Fuel System Common Rail EUI -
Governor Type Mechanical, ADEM™A4 ADEM� A4 -

Generator Set Dimensions

Length - Maximum 77.2 in 312.2 in -
Width - Maximum 43.3 in 123 in -
Height - Maximum 48 in 142.3 in -
Dry Weight - Genset (maximum) 2055 lb 45114 lb -
Length - Minimum - 242.77 in -
Width - Minimum - 83.1 in -
Height - Minimum - 87 in -
Dry Weight - Genset (minimum) - 42750 lb -