Compare Equipment Go Back

DE50 GC Generator Set (60 Hz)
C280-12 Generator Set (Medium Speed)

Generator Set Specifications

Maximum Rating 45 ekW 3640 ekW (60Hz), 4850 kVA (50Hz) 4000 ekW
Duty Cycle Standby Prime, Continuous Standby, Mission Critical, Prime, Continuous
Emissions/Fuel Strategy Non Regulated EPA Tier 4 Final, IMO Tier 2 Low Fuel, Tier 2
Voltage 220 to 480 Volts - 480 to 13800 Volts
Frequency 60 Hz 50 / 60 Hz 60 Hz
Speed 1800 rpm 900 / 1000 rpm 1800 rpm
Minimum Rating 45 ekW 3300 ekW (60Hz), 4400 kVA (50Hz) 3150 ekW
Standby Rating - - 4000 (no fan)/3900/3620(no fan)/3500 ekW
Prime Power Rating - - 3600 (no fan)/3500/3300 (no fan)/3180 ekW

Engine Specifications

Engine Model Cat® C3.3, In-line 3, 4-cycle diesel C280-12, V-12,4-Stroke Water-Cooled Diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel
Bore 4.1 in 11 in 6.89 in
Stroke 5 in 11.8 in 8.66 in
Displacement 201.4 in³ 13524 in³ 6456.31 in³
Compression Ratio 17.25:1 13:01 15.3:1
Aspiration Turbocharged TA Turbo Aftercooled
Fuel System Inline Direct unit injection Common Rail
Governor Type Mechanical Generator Set Monitoring System (GMS) ADEM� A4

Generator Set Dimensions

Length - Maximum 89.7 in 404 in 330.6 in
Width - Maximum 35.4 in 99.62 in 127.7 in
Height - Maximum 52 in 156.6 in 150.7 in
Dry Weight - Genset (maximum) 1031 lb 112690 lb 66200 lb
Length - Minimum - - 261.5 in
Width - Minimum - - 85.4 in
Height - Minimum - - 87.6 in
Dry Weight - Genset (minimum) - - 55100 lb
Add a Similar Product:
  • 3616 Generator Set (Medium Speed) Add
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-16 Generator Set Add