Option 2 - China Nonroad Stage III emissions standards, equivalent to U.S. EPA Tier 2
-
-
Engine Power - ISO 14396:2002
786 hp
426 hp
-
Gross Power - SAE J1995:2014
766 hp
434 hp
-
Net Power - SAE J1349:2011 - High Ambient
648 hp
-
-
Engine Power - ISO 14396: 2002
752 hp
-
-
Bore
5.4 in
5.4 in
-
Stroke
6 in
6.7 in
-
Displacement
1649.5 in³
927.6 in³
-
Peak Torque - Speed
2624 lb/ft
-
-
Torque Rise
18 %
33%
-
Note
Net power advertised is the power available at the flywheel when the engine is equipped with fan at minimum speed, air intake system, exhaust system, and alternator.
-
-
Net Power - SAE J1349:2011
-
405 hp
-
Net Power - ISO 9249:2007
-
405 hp
-
Peak Net Torque (1,300 rpm)
-
1479 lbf·ft
-
Maximum Altitude without Derating (U.S. EPA Tier 4 Final/EU Stage V)
-
9298 ft
-
Maximum Altitude without Derating (U.S. EPA Tier 3/EU Stage IIIA)
-
9098 ft
-
High Idle Speed
-
2300 r/min
-
Low Idle Speed
-
800 r/min
-
Note (1)
-
Net power advertised is the power available at the engine flywheel when the engine is equipped with a fan, air cleaner, clean emissions module and alternator.
-
Note (2)
-
Two engine emission configurations are available. One meets U.S. EPA Tier 4 Final, EU Stage V, Korea Stage V, and Japan 2014 emissions standards. The other meets Brazil MAR-1 emission standards, emitting equivalent to U.S. EPA Tier 3 and EU Stage IIIA.
Diesel Exhaust Fluid Tank (For Tier 4 Final/Stage V Only)
-
8.5 gal (US)
-
Hydraulic Tank Only
-
35.4 gal (US)
-
Hydraulic System - Implement/Steering
-
56.5 gal (US)
-
Note (1)
-
All nonroad Tier 4 Final, EU Stage V, and Japan 2014 (Tier 4 Final) diesel engines are required to use: – Ultra low sulfur diesel (ULSD) fuels containing 15 ppm (mg/kg) sulfur or less. – Cat engines are compatible with the following renewable, alternative
-
Air Conditioning System
Air Conditioning
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system co
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system co
-
Axles
Front
Fixed
Planetary – Fixed
-
Rear
Trunnion
Planetary – Oscillating
-
Oscillation Angle
8.5 °
±11°
-
Brakes
Brakes
Meets ISO 3540:2011
-
-
Sound Performance - Tier 4 Final / Stage V
Operator Sound Pressure Level (ISO 6396:2008)
72 dB(A)
73 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
116 dB(A)
113 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)*
114 dB(A)
-
-
Note (1)
*Sound suppression equipped
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives”
-
Note (2)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
** European Union Directive “2000/14/EC” as amended by “2005/88/EC.” and UK Noise Regulation 2001 No. 1701
-
Note (3)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (4)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Machine Sound Power Level (ISO 6395:2008)**
-
110 dB(A)
-
Note (5)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Sound Performance - Tier 2
Operator Sound Pressure Level (ISO 6396:2008)
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)
116 dB(A)
-
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)*
114 dB(A)
-
-
Note (1)
*Sound suppression equipped
-
-
Note (2)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (3)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (4)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Cab
ROPS/FOPS
ISO 3471:2008 and ISO 3449:2005 Level II Standards
-
-
Dimensions (Approximate)
Height - Top of ROPS
17.2 ft
-
-
Height - Top of Exhaust Pipe
16.6 ft
-
-
Height - Top of Hood
12.7 ft
10.5 ft
-
Ground Clearance
2 ft
1.8 ft
-
Centerline of Front Axle to Hitch
7.5 ft
6.1 ft
-
Centerline of Rear Axle to Edge of Bumper
12.5 ft
9.3 ft
-
Wheel Base
15.1 ft
12.1 ft
-
Length - With Blade on Ground
36.5 ft
-
-
Height to Top of Beacon
-
14.5 ft
-
Height - Top of Exhaust Stack
-
14.2 ft
-
Ground Clearance - Bumper
-
2.8 ft
-
Length - With Blade on Ground - Straight Blade
-
27.6 ft
-
Ground Clearance to Trunnion
-
1.45 ft
-
Height - Top of Cab
-
13.5 ft
-
Width Over Guardrails
-
10.94 ft
-
Braking System
Parking Brake
-
Drum and shoe, spring applied, hydraulic released
-
Brakes
-
Multi-disc wet (enclosed) 4 WHL
-
Sound Performance - Tier 3 / Stage IIIA
Operator Sound Pressure Level (ISO 6396:2008)
-
73 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
-
113 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
-
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)**
-
110 dB(A)
-
Note (1)
-
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives”
-
Note (2)
-
** European Union Directive “2000/14/EC” as amended by “2005/88/EC.” and UK Noise Regulation 2001 No. 1701
-
Note (3)
-
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (4)
-
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (5)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.