Option 2 - China Nonroad Stage III emissions standards, equivalent to U.S. EPA Tier 2
-
-
Engine Power - ISO 14396:2002
786 hp
-
-
Gross Power - SAE J1995:2014
766 hp
-
-
Net Power - SAE J1349:2011 - High Ambient
648 hp
-
-
Engine Power - ISO 14396: 2002
752 hp
-
-
Bore
5.4 in
5.7 in
-
Stroke
6 in
6.4 in
-
Displacement
1649.5 in³
1958 in²
-
Peak Torque - Speed
2624 lb/ft
-
-
Torque Rise
18 %
30 %
-
Note
Net power advertised is the power available at the flywheel when the engine is equipped with fan at minimum speed, air intake system, exhaust system, and alternator.
-
-
Emissions (U.S. EPA Tier 4 Final): Net Power ISO - 9249
Hydraulic System - Steering and Engine Cooling Fan - Tank Only
-
77 gal (US)
-
Note (1)
-
- All nonroad U.S. EPA Tier 4, European Union (EU) Stage IIIB and V, and Japan (MLIT) Step 4 diesel engines are required to use only Ultra Low Sulfer Diesel (ULSD) fuels containing 15 ppm (mg/kg) sulfer or less. Biodiesel blends up to B20 (20% blend by vo
-
Air Conditioning System
Air Conditioning
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system co
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a (Global Warming Potential = 1430). See the label or instruction manual for identification of the gas. If equipped with 1234yf (Global Warming Potential =
-
Axles
Front
Fixed
Fixed
-
Rear
Trunnion
Trunnion
-
Oscillation Angle
8.5 °
-
-
Brakes
Brakes
Meets ISO 3540:2011
Meets ISO 3540:2011
-
Sound Performance - Tier 4 Final / Stage V
Operator Sound Pressure Level (ISO 6396:2008)
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)
116 dB(A)
-
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)*
114 dB(A)
-
-
Note (1)
*Sound suppression equipped
-
-
Note (2)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (3)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (4)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Sound Performance - Tier 2
Operator Sound Pressure Level (ISO 6396:2008)
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)
116 dB(A)
-
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)*
114 dB(A)
-
-
Note (1)
*Sound suppression equipped
-
-
Note (2)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (3)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70 percent of the maximum engine cooling fan speed.
-
-
Note (4)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Cab
ROPS/FOPS
ISO 3471:2008 and ISO 3449:2005 Level II Standards
ISO 3471:2008 and ISO 3449:2005 Level II Standards
-
Dimensions (Approximate)
Height - Top of ROPS
17.2 ft
18.25 ft
-
Height - Top of Exhaust Pipe
16.6 ft
17.17 ft
-
Height - Top of Hood
12.7 ft
13 ft
-
Ground Clearance
2 ft
27 in
-
Centerline of Front Axle to Hitch
7.5 ft
9.67 ft
-
Centerline of Rear Axle to Edge of Bumper
12.5 ft
13.75 ft
-
Wheel Base
15.1 ft
19.25 ft
-
Length - With Blade on Ground
36.5 ft
44 ft
-
Weights
Operating Weight
-
224647 lb
-
Blades
Blade Capacities
-
30.5 to 44.8 m3 (40 to 58.6 yd3)
-
Sound Performance Levels
Sound Performance
-
• The machine sound power level was measured according to
ISO 6395:2008. The measurement was conducted at 70 percent
of the maximum engine cooling fan speed.
• The operator sound pressure level was measured according to
ISO 6396:2008. The measurement was